Shape-Sensing Robotic Bronchoscopy with Integrated Mobile Cone-Beam CT Guidance for Intraoperative Localization of Lung Tumors Using Indocyanine Green

Abdul Rahman Halawa iD, Miguel Belmonte, Kyle G Mitchell, Mara B Antonoff iD, Ravi Rajaram iD, Stephen Swisher, David C Rice, Roberto F Casal

Diagnostics · 18.06.2026 · 16 (12) · 1893

DOI: 10.3390/diagnostics16121893 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 18.06.2026. Verfasst von Abdul Rahman Halawa und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pulmonary and Critical Care Medicine, McGovern School of Medicine, Houston, TX 77030, USA. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: With increasing frequency in sublobar resections, accurate intraoperative localization has become essential to ensure adequate resection margins and spare lung parenchyma. Our study evaluates the efficacy of shape-sensing robotic bronchoscopy (SS-RAB) with integrated mobile cone-beam CT (mCBCT) for intraoperative localization of lung tumors using indocyanine green (ICG). We further aimed to explore the feasibility of a single intubation-single positioning technique for bronchoscopy and surgery.

Methods

We retrospectively reviewed patients who underwent SS-RAB with integrated mCBCT for ICG marking, followed by minimally invasive sublobar resection. ICG marking was deemed successful when it allowed the operative team to localize and resect the lesion with adequate pathology margins.

Results

A total of 28 patients with 30 pulmonary lesions from a single institution were included. Median tumor size was 10.5 mm (IQR, 8.7–14.6 mm) and distance from pleura 7.8 mm (IQR, 2.45–13.8 mm). Twenty lesions (66.6%) were solid, 5 lesions (16.6%) semi-solid, and 5 lesions (16.6%) ground-glass. ICG localization was successful in 28 lesions (93%). Nineteen patients (68%) were intubated only with a double-lumen endotracheal tube (DL-ETT), used for bronchoscopy and surgery, and in 10 patients (36%) ICG marking and surgery were both performed in lateral decubitus. One patient developed a small pneumothorax during bronchoscopy which did not prevent ICG injection.

Conclusions

SS-RAB with integrated mCBCT for ICG marking is successful and safe. Single intubation with DL-ETT and lateral decubitus positioning for both bronchoscopy and surgery are feasible. Further studies are needed to prove a potential increase in efficiency with this technique.

Schlagwörter

Stichwörter der Autor:innen

bronchoscopycone-beam computed tomographyindocyanine green

Autor:innen und Institutionen

  • Department of Pulmonary and Critical Care Medicine, McGovern School of Medicine, Houston, TX 77030, USA.
  • Texas Tech School of Medicine, Lubbock, TX 79430, USA.
  • Department of Cardiothoracic Surgery, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
  • Department of Pulmonary Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.

ORCID-Profile: Abdul Rahman Halawa, Mara B Antonoff, Ravi Rajaram

Zitieren

APA

Halawa, A. R., Belmonte, M., Mitchell, K. G., Antonoff, M. B., Rajaram, R., Swisher, S., Rice, D. C., & Casal, R. F. (2026). Shape-Sensing Robotic Bronchoscopy with Integrated Mobile Cone-Beam CT Guidance for Intraoperative Localization of Lung Tumors Using Indocyanine Green. Diagnostics, 16(12), 1893. https://doi.org/10.3390/diagnostics16121893

Vancouver

Halawa AR, Belmonte M, Mitchell KG, Antonoff MB, Rajaram R, Swisher S, et al. Shape-Sensing Robotic Bronchoscopy with Integrated Mobile Cone-Beam CT Guidance for Intraoperative Localization of Lung Tumors Using Indocyanine Green. Diagnostics. 2026;16(12):1893. doi:10.3390/diagnostics16121893

BibTeX
@article{Halawa2026,
  author = {Halawa, Abdul Rahman and Belmonte, Miguel and Mitchell, Kyle G and Antonoff, Mara B and Rajaram, Ravi and Swisher, Stephen and Rice, David C and Casal, Roberto F},
  title = {Shape-Sensing Robotic Bronchoscopy with Integrated Mobile Cone-Beam CT Guidance for Intraoperative Localization of Lung Tumors Using Indocyanine Green},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {12},
  pages = {1893},
  doi = {10.3390/diagnostics16121893}
}
Kostenlos starten →