EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of Slice Thickness on the Diagnostic Accuracy of Non-Contrast CT KUB for Renal Stone Detection

Syeda Kubra, Rida Fatima, Loqman Shah, Noreena Iftikar, Kamran Khan

Journal of Health, Wellness and Community Research · 28.04.2026 · 1-8

DOI: 10.61919/5634nf92 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Health, Wellness and Community Research, online erschienen am 28.04.2026. Verfasst von Syeda Kubra und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Non-contrast computed tomography of the kidneys, ureters, and bladder is the reference imaging modality for suspected urinary tract calculi, but its diagnostic performance may vary according to reconstruction slice thickness.

Objective

To evaluate the effect of 1 mm, 3 mm, and 5 mm axial slice thicknesses on renal stone detection, stone visibility, image noise, and radiologist diagnostic confidence in non-contrast CT KUB.

Methods

This comparative cross-sectional study included 109 patients aged 18–70 years who underwent non-contrast CT KUB for suspected renal or ureteric stones. Raw CT datasets were reconstructed into 1 mm, 3 mm, and 5 mm axial series and reviewed in randomized order by a blinded radiologist. Stone detection, visibility score, perceived image noise, and diagnostic confidence were recorded. Chi-square testing, one-way ANOVA, and logistic regression were used for analysis.

Results

Stone detection was highest on 1 mm slices (81.7%), followed by 3 mm (75.2%) and 5 mm slices (63.3%; p = 0.004). Good visibility declined from 73.4% at 1 mm to 32.1% at 5 mm, while high diagnostic confidence decreased from 56.9% to 11.9% (both p < 0.001). Compared with 1 mm slices, 5 mm slices showed significantly lower odds of stone detection (OR = 0.40, 95% CI: 0.23–0.70; p = 0.002).

Conclusion

Thin-slice 1 mm reconstruction improves renal stone detection, visibility, and diagnostic confidence on non-contrast CT KUB, despite higher perceived image noise

Zitieren

APA

Kubra, S., Fatima, R., Shah, L., Iftikar, N., & Khan, K. (2026). Effect of Slice Thickness on the Diagnostic Accuracy of Non-Contrast CT KUB for Renal Stone Detection. Journal of Health, Wellness and Community Research, 1-8. https://doi.org/10.61919/5634nf92

Vancouver

Kubra S, Fatima R, Shah L, Iftikar N, Khan K. Effect of Slice Thickness on the Diagnostic Accuracy of Non-Contrast CT KUB for Renal Stone Detection. Journal of Health, Wellness and Community Research. 2026:1-8. doi:10.61919/5634nf92

BibTeX
@article{Kubra2026,
  author = {Kubra, Syeda and Fatima, Rida and Shah, Loqman and Iftikar, Noreena and Khan, Kamran},
  title = {Effect of Slice Thickness on the Diagnostic Accuracy of Non-Contrast CT KUB for Renal Stone Detection},
  journal = {Journal of Health, Wellness and Community Research},
  year = {2026},
  pages = {1--8},
  doi = {10.61919/5634nf92}
}
Kostenlos starten →