Diagnostic accuracy of non-contrast MRI in frozen shoulder
Archives of Orthopaedic and Trauma Surgery · 17.01.2024 · 144 (3) · 1149-1159
DOI: 10.1007/s00402-023-05184-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, online erschienen am 17.01.2024. Verfasst von Thiago de Angelis Guerra Dotta und 6 weiteren Autor:innen. Beteiligte Einrichtung: Instituto de Ortopedia e Traumatologia, Hospital das Clinicas, Faculdade de Medicina, Universidade de Sao Paulo-IOTHCFMUSP, Rua Dr. Ovídio Pires de C…. Hauptthemen laut MEDLINE: Shoulder Joint, Bursitis. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Despite being the most used exam today, few studies have evaluated the accuracy of findings on non-contrast magnetic resonance imaging (MRI). The primary objective of the study was to evaluate the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of non-contrast MRI findings in frozen shoulder, isolated and in combination. The secondary objectives were to define the interobserver and intraobserver agreement of the assessments and the odds ratio for frozen shoulder because of the various findings of MRI. METHODS: A retrospective diagnostic accuracy study comparing non-contrast MRI findings between the frozen shoulder group and the control group. Sensitivity, specificity, positive and negative predictive value, accuracy, odds ratio, interobserver and intraobserver agreement were calculated for each finding and their possible associations. RESULTS: The hyperintensity on capsule in the axillary recess presented 84% sensitivity, 94% specificity, and 89% accuracy. The obliteration of the subcoracoid fat triangle in the rotator interval had sensitivity 34%, specificity 82% and accuracy 58%. For coracohumeral ligament thickness ≥ 2 mm had specificity 66%, 48% specificity and 57% accuracy. Capsule thickness in the axillary recess ≥ 4 mm resulted in 54% sensitivity, 82% specificity, and 68% accuracy. Regarding interobserver agreement, only the posteroinferior and posterosuperior quadrants showed moderate results, and all the others showed strong reliability. The odds ratio for hyperintensity in the axillary recess was 82.3 for frozen shoulder. The association of these findings increased specificity (95%). CONCLUSION: The accuracy of non-contrast magnetic resonance imaging is high for diagnosing frozen shoulder, especially when evaluating the hyperintensity of the axillary recess. The exam has high reliability and reproducibility. The presence of an association of signs increases the specificity of the test. LEVEL OF EVIDENCE: Level III, study of diagnostic test.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Instituto de Ortopedia e Traumatologia, Hospital das Clinicas, Faculdade de Medicina, Universidade de Sao Paulo-IOTHCFMUSP, Rua Dr. Ovídio Pires de Campos 333 3 Floor, Cerqueira Cesar, São Paulo, SP, 05403-010, Brazil.…
- Instituto de Ortopedia e Traumatologia, Hospital das Clinicas, Faculdade de Medicina, Universidade de Sao Paulo-IOTHCFMUSP, Rua Dr. Ovídio Pires de Campos 333 3 Floor, Cerqueira Cesar, São Paulo, SP, 05403-010, Brazil.
- Hospital do Coração-HCor, São Paulo, SP, Brazil.
Zitieren
APA
de Angelis Guerra Dotta, T., Assunção, J. H., Baptista, E., E Silva, F. B. A., Gracitelli, M. E. C., Neto, A. A. F., & Malavolta, E. A. (2024). Diagnostic accuracy of non-contrast MRI in frozen shoulder. Archives of Orthopaedic and Trauma Surgery, 144(3), 1149-1159. https://doi.org/10.1007/s00402-023-05184-3
Vancouver
de Angelis Guerra Dotta T, Assunção JH, Baptista E, E Silva FBA, Gracitelli MEC, Neto AAF, et al. Diagnostic accuracy of non-contrast MRI in frozen shoulder. Archives of Orthopaedic and Trauma Surgery. 2024;144(3):1149-1159. doi:10.1007/s00402-023-05184-3
BibTeX
@article{deAngelisGuerraDotta2024,
author = {de Angelis Guerra Dotta, Thiago and Assunção, Jorge Henrique and Baptista, Eduardo and E Silva, Fernando Brandão Andrade and Gracitelli, Mauro Emilio Conforto and Neto, Arnaldo Amado Ferreira and Malavolta, Eduardo Angeli},
title = {Diagnostic accuracy of non-contrast MRI in frozen shoulder},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2024},
volume = {144},
number = {3},
pages = {1149--1159},
doi = {10.1007/s00402-023-05184-3}
}
EUVIMED