EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Influence of Implant Number on Maximum Bite Force of Maxillary Implant-Retained Overdentures Opposed by Mandibular Two-Implant Overdentures: A Prospective Randomized Crossover Clinical Study

Shaimaa Ayman Hassan, Noha Hosny El-Shaheed, Mai Ahmed Haggag, Fatma Ahmad El Waseef

Mansoura Journal of Dentistry · 01.01.2026 · 13 (3) · 1-1

DOI: 10.61793/2812-5479.1193 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mansoura Journal of Dentistry, online erschienen am 01.01.2026. Verfasst von Shaimaa Ayman Hassan und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To assess the effect of implant number (three, four, and five unsplinted implants) on maximum bite force (MBF) of maxillary implant overdentures opposed by two‑implant mandibular overdentures. Materials and Methods: Twelve completely edentulous cases were recruited from the Outpatient Clinic, Prosthodontics Department. Five implants were placed in the maxilla (midline, bilateral canines, and bilateral molars). Using a randomized crossover design, three loading configurations were evaluated sequentially for three months each: three implants (midline and canines), five implants (all implants), and four implants (canines and molars). Maximum bite force was determined utilizing a GM10 occlusal force meter (Nagano Keiki Co., Ltd., Tokyo, Japan) at the anterior and posterior regions for each loading configuration after 3 months. Three readings per site were recorded and averaged. Statistical analysis was performed utilizing one-way ANOVA and Tukey’s post hoc test (α = 0.05).

Results

Posterior MBF significantly elevated with increasing implant number. The five-implant configuration demonstrated the highest posterior values, followed by the four-implant configuration, while the three-implant configuration illustrated the lowest values. A significant variance was observed between the three-implant configuration and both five -and a four-implant configuration in anterior MBF, while no significant difference exists between five- and four-implant configurations.

Conclusion

Increasing the number of supporting implants improved maximum bite force in maxillary implant-retained overdentures, particularly in the posterior region. Although anterior MBF also improved when more than three implants were used, no significant difference was observed between the four- and five-implant configurations. Clinically, four implants may provide a practical alternative to five implants when anatomical or financial limitations exist.

Zitieren

APA

Hassan, S. A., El-Shaheed, N. H., Haggag, M. A., & Waseef, F. A. E. (2026). Influence of Implant Number on Maximum Bite Force of Maxillary Implant-Retained Overdentures Opposed by Mandibular Two-Implant Overdentures: A Prospective Randomized Crossover Clinical Study. Mansoura Journal of Dentistry, 13(3), 1-1. https://doi.org/10.61793/2812-5479.1193

Vancouver

Hassan SA, El-Shaheed NH, Haggag MA, Waseef FAE. Influence of Implant Number on Maximum Bite Force of Maxillary Implant-Retained Overdentures Opposed by Mandibular Two-Implant Overdentures: A Prospective Randomized Crossover Clinical Study. Mansoura Journal of Dentistry. 2026;13(3):1-1. doi:10.61793/2812-5479.1193

BibTeX
@article{Hassan2026,
  author = {Hassan, Shaimaa Ayman and El-Shaheed, Noha Hosny and Haggag, Mai Ahmed and Waseef, Fatma Ahmad El},
  title = {Influence of Implant Number on Maximum Bite Force of Maxillary Implant-Retained Overdentures Opposed by Mandibular Two-Implant Overdentures: A Prospective Randomized Crossover Clinical Study},
  journal = {Mansoura Journal of Dentistry},
  year = {2026},
  volume = {13},
  number = {3},
  pages = {1--1},
  doi = {10.61793/2812-5479.1193}
}
Kostenlos starten →