ENZYME-FREE COLOURIMETRIC SENSOR BASED ON ZIRCONIUM-BASED MOF FOR THE DETECTION OF MALATHION

Rui Liu, WenJia Chen, JunXian Li, Run Wang, Liang Dong

Eurasia Journal of Science and Technology · 08.04.2026 · 8 (2) · 9-20

DOI: 10.61784/ejst3141 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Eurasia Journal of Science and Technology, online erschienen am 08.04.2026. Verfasst von Rui Liu und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address the issues of enzyme inactivation, complex procedures, and dependence on large-scale equipment in traditional organophosphorus pesticide detection, we developed an enzyme-free colourimetric sensor employing Hemin@UiO-66 composite nanomaterials for the rapid and accurate detection of malathion. The UiO-66 metal-organic framework was synthesised using the solvothermal method, while the Hemin@UiO-66nanoenzyme was produced through post-modification with hemin chloride (Hemin). The structural characteristics of the material were analysed using Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), scanning electron microscopy (SEM), and X-ray photoelectron spectroscopy (XPS).Thisnanoenzyme demonstrated remarkable peroxidase-like activity, effectively catalysing the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) to blue-coloured oxidised TMB (oxTMB) in the presence of hydrogen peroxide (H₂O₂). Malathion interacts with the active sites of the material via Zr-O-P coordination, which significantly inhibits the catalytic activity of thenanoenzyme. As a result, the colour of the system gradually diminished with increasing malathion concentration. Under optimised conditions, a strong linear correlation was established between the change in absorbance of the sensor and malathion concentration, spanning from 5 to 270 ng/mL, with a detection limit as low as 4.23 ng/mL (3σ) and a detection time of 20 minutes. This method exhibited excellent selectivity, stability, repeatability, and anti-interference capabilities. The recovery rates of malathion in spiked real samples ranged from 95.3% to 104.7%, accompanied by a relative standard deviation (RSD) of less than 4.2%. By eliminating the need for biological enzymes, this sensor facilitates straightforward operation and rapid response, thereby providing an innovative approach for the on-site rapid detection of malathion residues in food.

Zitieren

APA

Liu, R., Chen, W., Li, J., Wang, R., & Dong, L. (2026). ENZYME-FREE COLOURIMETRIC SENSOR BASED ON ZIRCONIUM-BASED MOF FOR THE DETECTION OF MALATHION. Eurasia Journal of Science and Technology, 8(2), 9-20. https://doi.org/10.61784/ejst3141

Vancouver

Liu R, Chen W, Li J, Wang R, Dong L. ENZYME-FREE COLOURIMETRIC SENSOR BASED ON ZIRCONIUM-BASED MOF FOR THE DETECTION OF MALATHION. Eurasia Journal of Science and Technology. 2026;8(2):9-20. doi:10.61784/ejst3141

BibTeX
@article{Liu2026,
  author = {Liu, Rui and Chen, WenJia and Li, JunXian and Wang, Run and Dong, Liang},
  title = {ENZYME-FREE COLOURIMETRIC SENSOR BASED ON ZIRCONIUM-BASED MOF FOR THE DETECTION OF MALATHION},
  journal = {Eurasia Journal of Science and Technology},
  year = {2026},
  volume = {8},
  number = {2},
  pages = {9--20},
  doi = {10.61784/ejst3141}
}