Diboronic-Acid-Based Electrochemical Sensor for Enzyme-Free Selective and Sensitive Glucose Detection
Biosensors · 09.02.2023 · 13 (2) · 248
DOI: 10.3390/bios13020248 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 09.02.2023. Verfasst von Joong-Hyun Kim und 6 weiteren Autor:innen. Beteiligte Einrichtung: Drug Manufacturing Center, Daegu-Gyeongbuk Medical Innovation Foundation, 80, Chumbok-ro, Dong-Gu, Daegu 41061, Republic of Korea. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea Grant.
Abstract (Originalsprache)
A diboronic acid anthracene-based fluorescent system for detecting blood glucose could be used for 180 days. However, there has not yet been a boronic acid immobilized electrode to selectively detect glucose in a signal-increased way. Considering malfunctions of sensors at high sugar levels, the electrochemical signal should be increased proportionally to the glucose concentration. Therefore, we synthesized a new diboronic acid derivative and fabricated the derivative-immobilized electrodes for the selective detection of glucose. We performed cyclic voltammetry and electrochemical impedance spectroscopy with an Fe(CN)63−/4− redox pair for detecting glucose in the range of 0–500 mg/dL. The analysis revealed increased electron-transfer kinetics such as increased peak current and decreased semicircle radius of Nyquist plots as the glucose concentration increased. The cyclic voltammetry and impedance spectroscopy showed that the linear detection range of glucose was 40 to 500 mg/dL with limits of detection of 31.2 mg/dL and 21.5 mg/dL, respectively. We applied the fabricated electrode to detect glucose in artificial sweat and obtained 90% of the performance of the electrodes in PBS. Cyclic voltammetry measurements of other sugars such as galactose, fructose, and mannitol also showed linear increased peak currents proportional to the concentrations of the tested sugars. However, the slopes of the sugars were lower than that of glucose, indicating selectivity for glucose. These results proved the newly synthesized diboronic acid is a promising synthetic receptor for developing a long-term usable electrochemical sensor system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Drug Manufacturing Center, Daegu-Gyeongbuk Medical Innovation Foundation, 80, Chumbok-ro, Dong-Gu, Daegu 41061, Republic of Korea.
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, 80, Chumbok-ro, Dong-gu, Daegu 41061, Republic of Korea.
- Department of Biomedical Engineering, Chungbuk National University, 1, Chungdae-ro, Seowon-gu, Cheongju 28644, Republic of Korea.
ORCID-Profile: Chul-Soon Park
Förderung
- National Research Foundation of Korea Grant
Zitieren
APA
Kim, J. H., Choi, H., Park, C. S., Yim, H. S., Kim, D., Lee, S., & Lee, Y. (2023). Diboronic-Acid-Based Electrochemical Sensor for Enzyme-Free Selective and Sensitive Glucose Detection. Biosensors, 13(2), 248. https://doi.org/10.3390/bios13020248
Vancouver
Kim JH, Choi H, Park CS, Yim HS, Kim D, Lee S, et al. Diboronic-Acid-Based Electrochemical Sensor for Enzyme-Free Selective and Sensitive Glucose Detection. Biosensors. 2023;13(2):248. doi:10.3390/bios13020248
BibTeX
@article{Kim2023,
author = {Kim, Joong-Hyun and Choi, Hongsik and Park, Chul-Soon and Yim, Heung-Seop and Kim, Dongguk and Lee, Sungmin and Lee, Yeonkeong},
title = {Diboronic-Acid-Based Electrochemical Sensor for Enzyme-Free Selective and Sensitive Glucose Detection},
journal = {Biosensors},
year = {2023},
volume = {13},
number = {2},
pages = {248},
doi = {10.3390/bios13020248}
}
EUVIMED