EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Study on Multiple Load Conditions Analysis for a Conventional Bicycle vs. a Variable-Chain Stay-Length (VCL) Bicycle De1

Meor Rashydan Abdullah, Muhammad Izzat Nor Ma’arof, Winson Wong Zu Xian, Suresh Akshith, Girma Tadesse Chala

Journal of Innovation and Technology · 2023

DOI: 10.61453/joit.v2023no01 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Innovation and Technology, 2023. Verfasst von Meor Rashydan Abdullah und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study was to study on the multiple loading conditions on a varied bicycle’s chain stay designs. The benchmark for this study was a conventional bicycle chassis design which is available in the market. The specification details of this chassis were obtained from the manufacturer’s website. The new design was a Variable-Chain Stay-Length (VCL) configuration. The purpose for the VCL is to allow room for the cyclist to attach to have an extra space for placing the cargo. The VCL is rated as VCL De1 and was developed in reference to the aforementioned benchmark chassis. Both chassis were developed via the use of Computer Aided Design (CAD). The chassis were then analyzed via Finite Element Analysis (FEA) software for the following loading conditions: (i) Static start-up (ii) Steady pedaling (iii) Vertical loading (iv) Rear wheel braking. The Maximum Equivalent (von Mises) Stress (MPa) recorded for the loading conditions were as follow: (i) Benchmark Chassis: (Condition 1) 117.58MPa, (Condition 2) 120.51MPa, (Condition 3) 235.15MPa, (Condition 4) 99.40MPa, whilst, for the (ii) VCL De1: (Condition 1) 123.43MPa, (Condition 2) 126.24MPa, (Condition 3) 246.85MPa, (Condition 4) 189.13MPa respectively. Adding to this, the safety factor for the aforementioned conditions were also obtained as follow: (i) Benchmark Chassis: (Condition 1) 2.38, (Condition 2) 2.32, (Condition 3) 1.19, (Condition 4) 2.82, whilst, (ii) VCL De1: (Condition 1) 2.03, (Condition 2) 1.98, (Condition 3) 1.01, (Condition 4) 0.13. In short, the assessments were a success. It could be noted that the safety factors for the VCL De1 is above 1.0 for Condition 1 to 3, yet, at condition 4 is rated at 87% below the Safety Factor. Hence, this result is indeed undesirable. Thus, the VCL De1 is not suitable for usage due to the high possibility of structural failure. Further improvement on design iteration is warranted for the VCL chassis

Zitieren

APA

Abdullah, M. R., Ma’arof, M. I. N., Xian, W. W. Z., Akshith, S., & Chala, G. T. (2023). A Study on Multiple Load Conditions Analysis for a Conventional Bicycle vs. a Variable-Chain Stay-Length (VCL) Bicycle De1. Journal of Innovation and Technology. https://doi.org/10.61453/joit.v2023no01

Vancouver

Abdullah MR, Ma’arof MIN, Xian WWZ, Akshith S, Chala GT. A Study on Multiple Load Conditions Analysis for a Conventional Bicycle vs. a Variable-Chain Stay-Length (VCL) Bicycle De1. Journal of Innovation and Technology. 2023. doi:10.61453/joit.v2023no01

BibTeX
@article{Abdullah2023,
  author = {Abdullah, Meor Rashydan and Ma’arof, Muhammad Izzat Nor and Xian, Winson Wong Zu and Akshith, Suresh and Chala, Girma Tadesse},
  title = {A Study on Multiple Load Conditions Analysis for a Conventional Bicycle vs. a Variable-Chain Stay-Length (VCL) Bicycle De1},
  journal = {Journal of Innovation and Technology},
  year = {2023},
  doi = {10.61453/joit.v2023no01}
}
Kostenlos starten →