Measurements and Prediction of Ash Deposition in a Cyclone-Fired Boiler Operating under Variable Load Conditions
Fluids · 23.11.2023 · 8 (12) · 305
DOI: 10.3390/fluids8120305 ↗Kurz gefasst
Fachartikel in der Zeitschrift Fluids, online erschienen am 23.11.2023. Verfasst von Gautham Krishnamoorthy und 5 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University Coal Research Program being administered by DOE-NETL.
Abstract (Originalsprache)
Measurements of ash deposition rates were made between the secondary superheater and reheater sections of a 450 MW cyclone-fired lignite boiler as the operational load varied from 33 to 100%. Significant reductions in deposition rates with a decrease in operational load were observed. To uncover the causative mechanisms behind these observations, operational data from the power plant were used to carry out computational fluid dynamic (CFD) simulations of the boiler. After ascertaining that the gas temperatures and velocities at various sections within the boiler were being represented adequately, decoupled simulations of the ash deposition process on the deposit probe were carried out using a finely resolved boundary layer mesh. Fly ash particle size distribution (PSD) and its concentration for the decoupled calculations were determined from stand-alone cyclone barrel simulations. The ash partitioning (mass %) between the fly ash and slag was found to be ~50:50, which was in line with previous field observations, and it did not vary significantly across different cyclone loads. The predicted PSD of the deposit ash was concentrated in the size range 10–30 microns, which was in agreement with cross-sectional images of the deposit obtained from the measurements. At lower loads, sharp variations in the deposition rates were predicted in the gas temperature range 950–1150 K. The particle kinetic energy—particle viscosity-based capture methodology utilized in this study in conjunction with appropriate ash compositions, ash viscosity models and gas temperature estimates can help estimate slagging propensities at different loads reasonably well in these systems.
Förderung
- University Coal Research Program being administered by DOE-NETL
Zitieren
APA
Krishnamoorthy, G., Bloom, E., Viswanathan, K., Patwardhan, S. S., Stadem, D. J., & Benson, S. (2023). Measurements and Prediction of Ash Deposition in a Cyclone-Fired Boiler Operating under Variable Load Conditions. Fluids, 8(12), 305. https://doi.org/10.3390/fluids8120305
Vancouver
Krishnamoorthy G, Bloom E, Viswanathan K, Patwardhan SS, Stadem DJ, Benson S. Measurements and Prediction of Ash Deposition in a Cyclone-Fired Boiler Operating under Variable Load Conditions. Fluids. 2023;8(12):305. doi:10.3390/fluids8120305
BibTeX
@article{Krishnamoorthy2023,
author = {Krishnamoorthy, Gautham and Bloom, Evan and Viswanathan, Krishnamoorthy and Patwardhan, Shuchita Sanjay and Stadem, David John and Benson, Steve},
title = {Measurements and Prediction of Ash Deposition in a Cyclone-Fired Boiler Operating under Variable Load Conditions},
journal = {Fluids},
year = {2023},
volume = {8},
number = {12},
pages = {305},
doi = {10.3390/fluids8120305}
}
EUVIMED