Optimization of HEMA composition in polymer gel dosimeters for cost-effective radiation measurement
Proceedings of the Nigerian Society of Physical Sciences · 04.06.2026 · 327
DOI: 10.61298/pnspsc.2026.3.327 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the Nigerian Society of Physical Sciences, online erschienen am 04.06.2026. Verfasst von Muhammad Alhassan und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Polymer gel dosimeters (PGDs) are potential tools for radiation measurement in radiotherapy treatment planning systems (TPSs) and nuclear energy monitoring. Optimization of monomer composition is an essential aspect of PGD formulation because it helps achieve optimal dosimetric performance. In this study, 2 hydroxyethyl methacrylate (HEMA), in combination with N,N'-methylene-bis-acrylamide (Bis), was optimized to improve dose-evaluation efficiency and cost-effectiveness. The results show that the HEMA-free formulation containing 2% (w/w) Bis had the lowest sensitivity. When Bis and HEMA were both added, sensitivity increased linearly with increasing total monomer percentage (%T). However, when the weight fraction (WF) of Bis was fixed and the co monomer percentage (%C) of HEMA increased from 0 to 60%, sensitivity decreased beyond the optimal value because of exhaustion of the vinyl groups in Bis. The mass density of the HEMA--Bis PGDs (≈ 1.04 g cm−3), their electron density (ρe = 3.42 × 1023–3.43 × 1023 cm−3), their number of electrons per unit mass (ne = 3.28 × 1023–3.30 × 1023 g−1), and their effective atomic number (Zeff = 7.3624–7.4176) are comparable to those of water and muscle tissue, indicating water and tissue equivalence. These findings not only yield a more efficient HEMA-based PGD but also improve cost-effectiveness, thereby increasing affordability for healthcare applications.
Zitieren
APA
Alhassan, M., Rahman, A. A., & Mustafa, I. S. (2026). Optimization of HEMA composition in polymer gel dosimeters for cost-effective radiation measurement. Proceedings of the Nigerian Society of Physical Sciences, 327. https://doi.org/10.61298/pnspsc.2026.3.327
Vancouver
Alhassan M, Rahman AA, Mustafa IS. Optimization of HEMA composition in polymer gel dosimeters for cost-effective radiation measurement. Proceedings of the Nigerian Society of Physical Sciences. 2026:327. doi:10.61298/pnspsc.2026.3.327
BibTeX
@article{Alhassan2026,
author = {Alhassan, Muhammad and Rahman, Azhar Abdul and Mustafa, Iskandar Shahrim},
title = {Optimization of HEMA composition in polymer gel dosimeters for cost-effective radiation measurement},
journal = {Proceedings of the Nigerian Society of Physical Sciences},
year = {2026},
pages = {327},
doi = {10.61298/pnspsc.2026.3.327}
}