EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Factors influencing the thermal stability of HEMA polymer gel dosimeters for clinical radiotherapy

Muhammad Alhassan, Azhar Abdul Rahman, Iskandar Shahrim Mustafa, Kabiru Alhaji Bala

Journal of the Nigerian Society of Physical Sciences · 21.03.2026 · 3063

DOI: 10.46481/jnsps.2026.3063 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Nigerian Society of Physical Sciences, online erschienen am 21.03.2026. Verfasst von Muhammad Alhassan und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Thermal stability is an essential feature required for practical applicability of gel dosimeters in radiation therapy planning system (TPS). This study pioneers a comprehensive experimental study of various factors that influence thermal stability of Polymer Gel Dosimeters (PGDs) by investigating the impact of gelatin source and its weight fraction (WF), type and WF of antioxidant, presence of maltose as a disaccharide additive, and the storage time post manufacturing, on the thermal properties of 2-hydroxymethyl methacrylate (HEMA) PGD. Results show that in terms of fast gelation and gel strength, gelatin from bovine skin outperforms gelatin from cold water fish, withstanding temperature up to 11 ?C aboves its Tm, and tetrakis(hydroxymethyl)phosphonium chloride (THPC) outperforms ascorbic acid (AscA), and sample with maltose additive outperforms sample without maltose. The melting rate (Rm) increases with the temperature difference above Tm, and storage time post manufacturing, improves the thermal stability. These findings contribute to the identification of the causes of gel instability and propose the possible solutions that could lead to more accurate assessments and maintenance of dose distribution in three-dimension (3D), and to extend the shelf life of PGDs.

Zitieren

APA

Alhassan, M., Rahman, A. A., Mustafa, I. S., & Bala, K. A. (2026). Factors influencing the thermal stability of HEMA polymer gel dosimeters for clinical radiotherapy. Journal of the Nigerian Society of Physical Sciences, 3063. https://doi.org/10.46481/jnsps.2026.3063

Vancouver

Alhassan M, Rahman AA, Mustafa IS, Bala KA. Factors influencing the thermal stability of HEMA polymer gel dosimeters for clinical radiotherapy. Journal of the Nigerian Society of Physical Sciences. 2026:3063. doi:10.46481/jnsps.2026.3063

BibTeX
@article{Alhassan2026,
  author = {Alhassan, Muhammad and Rahman, Azhar Abdul and Mustafa, Iskandar Shahrim and Bala, Kabiru Alhaji},
  title = {Factors influencing the thermal stability of HEMA polymer gel dosimeters for clinical radiotherapy},
  journal = {Journal of the Nigerian Society of Physical Sciences},
  year = {2026},
  pages = {3063},
  doi = {10.46481/jnsps.2026.3063}
}
Kostenlos starten →