EUVIMEDEUVIMED entdecken
Open Access

Microleakage of zinc oxide eugenol, resin, calcium hydroxide, bioceramic and bioactive glass sealers using stereomicroscope: An in vitro study

Shivani Rawat, Anu Narang, Santosh Kumar Singh, Gayatri H Giramkar, Sadhvi Pateriya, Naman Keshwani

Bioinformation · 30.06.2026 · 22 (6) · 3723-3727

DOI: 10.6026/973206300223723 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioinformation, online erschienen am 30.06.2026. Verfasst von Shivani Rawat und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Endodontics, People's College of Dental Sciences and Research Centre, People's University, Bhopal, Madhya Pr…. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microleakage is a major cause of endodontic treatment failure due to inadequate sealing ability of root canal sealers. Therefore, it is of interest to evaluate the microleakage of five different root canal sealers using stereomicroscope. Seventy extracted premolars were divided into five groups (n=14) and obturated using respective sealers. Bioactive glass sealer showed lowest microleakage (1.6400 ± 0.3908 mm), while zinc oxide eugenol showed highest microleakage (5.8200 ± 0.6820 mm). Differences were statistically significant (p

Schlagwörter

Stichwörter der Autor:innen

Microleakagebioactive glassbioceramic sealerdye penetrationroot canal sealers

Autor:innen und Institutionen

  • Department of Conservative Dentistry and Endodontics, People's College of Dental Sciences and Research Centre, People's University, Bhopal, Madhya Pradesh, India.

Zitieren

APA

Rawat, S., Narang, A., Singh, S. K., Giramkar, G. H., Pateriya, S., & Keshwani, N. (2026). Microleakage of zinc oxide eugenol, resin, calcium hydroxide, bioceramic and bioactive glass sealers using stereomicroscope: An in vitro study. Bioinformation, 22(6), 3723-3727. https://doi.org/10.6026/973206300223723

Vancouver

Rawat S, Narang A, Singh SK, Giramkar GH, Pateriya S, Keshwani N. Microleakage of zinc oxide eugenol, resin, calcium hydroxide, bioceramic and bioactive glass sealers using stereomicroscope: An in vitro study. Bioinformation. 2026;22(6):3723-3727. doi:10.6026/973206300223723

BibTeX
@article{Rawat2026,
  author = {Rawat, Shivani and Narang, Anu and Singh, Santosh Kumar and Giramkar, Gayatri H and Pateriya, Sadhvi and Keshwani, Naman},
  title = {Microleakage of zinc oxide eugenol, resin, calcium hydroxide, bioceramic and bioactive glass sealers using stereomicroscope: An in vitro study},
  journal = {Bioinformation},
  year = {2026},
  volume = {22},
  number = {6},
  pages = {3723--3727},
  doi = {10.6026/973206300223723}
}
Kostenlos starten →