Effect of light-emitting diode curing tip distance on shear bond strength in metal, ceramic and polycarbonate orthodontic brackets: An in vitro study
Bioinformation · 31.05.2026 · 22 (5) · 2750-2755
DOI: 10.6026/973206300222750 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinformation, online erschienen am 31.05.2026. Verfasst von Hemadri S und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, CKS Teja Institute of Dental Sciences and Research, Tirupati, Andhra Pradesh, India. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Adequate shear bond strength between orthodontic brackets and enamel is essential for successful treatment. However, the effect of LED curing tip distance on different bracket materials remains unclear. Therefore, it is of interest to evaluate the shear bond strength of stainless-steel, polycarbonate and monocrystalline ceramic and polycrystalline brackets at varying LED curing distances. Two hundred premolars were divided by bracket type and curing distances (0, 6, 8, 10 and 15 mm) and bond strength was tested using a universal testing machine. Results showed high bond strength at 0 mm with a significant reduction as distance increased, with stainless-steel and ceramic brackets maintaining clinically acceptable values while polycarbonate brackets showed reduced strength at greater distances. Both bracket material and curing distance significantly influenced shear bond strength, emphasizing the need to minimize curing distance for optimal bonding performance.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, CKS Teja Institute of Dental Sciences and Research, Tirupati, Andhra Pradesh, India.
- Department of Orthodontics, Yashwantrao Chavan Dental College, Ahilyanagar, Maharashtra, India.
Zitieren
APA
S, H., S V, K. V., Palagiri, F. B., Tanpure, V. R., Sagar, V., & N, T. (2026). Effect of light-emitting diode curing tip distance on shear bond strength in metal, ceramic and polycarbonate orthodontic brackets: An in vitro study. Bioinformation, 22(5), 2750-2755. https://doi.org/10.6026/973206300222750
Vancouver
S H, S V KV, Palagiri FB, Tanpure VR, Sagar V, N T. Effect of light-emitting diode curing tip distance on shear bond strength in metal, ceramic and polycarbonate orthodontic brackets: An in vitro study. Bioinformation. 2026;22(5):2750-2755. doi:10.6026/973206300222750
BibTeX
@article{S2026,
author = {S, Hemadri and S V, Kala Vani and Palagiri, Firoz Babu and Tanpure, Vijaysinh R and Sagar, VLakshmi and N, Thejaswini},
title = {Effect of light-emitting diode curing tip distance on shear bond strength in metal, ceramic and polycarbonate orthodontic brackets: An in vitro study},
journal = {Bioinformation},
year = {2026},
volume = {22},
number = {5},
pages = {2750--2755},
doi = {10.6026/973206300222750}
}
EUVIMED