Marginal fit of titanium and zirconia abutments: Micro-CT analysis
Bioinformation · 31.03.2026 · 22 (3) · 1809-1814
DOI: 10.6026/973206300221809 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinformation, online erschienen am 31.03.2026. Verfasst von Harikrishna Modalavalasa und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, GITAM Dental College & Hospital, Visakhapatnam, India. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
The lack of high-resolution three-dimensional evidence comparing marginal fit and biological sealing between CAD/CAM titanium and zirconia abutments manufactured under identical digital workflows remains a critical gap in implant prosthodontics. Digital workflows enhance implant prosthodontic precision, yet differences in marginal fit between CAD/CAM titanium and zirconia abutments are unclear. Therefore, it is of interest to assess marginal adaptation, internal fit and bacterial microleakage of 60 digitally fabricated abutments using micro-CT and bacterial infiltration tests. Titanium abutments showed smaller marginal gaps (12.4 ± 3.8 μm) and higher internal contact (73.2 ± 8.4%) than zirconia (23.7 ± 6.2 μm; 58.9 ± 11.7%) (p < 0.001). Bacterial leakage was lower in titanium (13.3%) compared to zirconia (43.3%) (P < 0.05). Thus, CAD/CAM titanium abutments demonstrated superior marginal fit, internal adaptation and microbial sealing.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, GITAM Dental College & Hospital, Visakhapatnam, India.
- Department of Prosthodontics, Drs. S & NR SIDS, Gannavaram, India.
- Private Practitioner, Prosthodontist & Implantologist, Mahavir Arogya Sansthan, Bihar, Patna, India.
- Department of Prosthodontics, Manav Rachna Dental College, Faridabad, Haryana, India.
- Private Practitioner, Oral and Maxillofacial Surgeon, Mahavir Arogya Sansthan, Patna, India.
Zitieren
APA
Modalavalasa, H., Bhargavi, K., Ampolu, R., Kant Pandey, P. K., Shukla, S., & Jha, G. K. (2026). Marginal fit of titanium and zirconia abutments: Micro-CT analysis. Bioinformation, 22(3), 1809-1814. https://doi.org/10.6026/973206300221809
Vancouver
Modalavalasa H, Bhargavi K, Ampolu R, Kant Pandey PK, Shukla S, Jha GK. Marginal fit of titanium and zirconia abutments: Micro-CT analysis. Bioinformation. 2026;22(3):1809-1814. doi:10.6026/973206300221809
BibTeX
@article{Modalavalasa2026,
author = {Modalavalasa, Harikrishna and Bhargavi, Katta and Ampolu, Ramesh and Kant Pandey, Prachi Krishna and Shukla, Supriya and Jha, Gaurav Kumar},
title = {Marginal fit of titanium and zirconia abutments: Micro-CT analysis},
journal = {Bioinformation},
year = {2026},
volume = {22},
number = {3},
pages = {1809--1814},
doi = {10.6026/973206300221809}
}
EUVIMED