Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2026. Verfasst von Yuichi Takao. Beteiligte Einrichtung: Department of Radiology, Fukuoka Tokushukai Hospital, Tokushukai Medical Corporation. Hauptthemen laut MEDLINE: Contrast Media, Computed Tomography Angiography, Lower Extremity, Thorax. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study aimed to evaluate the usefulness of variable helical pitch scanning (vHP) on the uniformity of contrast enhancement in wide-range computed tomography angiography (CTA) from the chest to the lower extremities using contrast media administered at 400 mgI/kg over 20 seconds. METHODS: Using the double-level test bolus injection (DLTI) method to determine the contrast arrival time, CTA scans were performed with a fixed-HP method (n=20) and a variable-HP method using vHP (n=20). The CT numbers at five major arterial regions were compared, and a visual assessment was also conducted. RESULTS: Compared with the fixed-HP method, the variable-HP method significantly increased the CT number in the abdominal aorta and femoral arteries (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaComputed Tomography AngiographyLower ExtremityThoraxTomography, Spiral ComputedHumansMaleFemaleMiddle AgedAgedAdult

Stichwörter der Autor:innen

chest to lower extremitycomputed tomography angiography (CTA)contrast enhancementdouble-level test bolus injectionvariable helical pitch scanning (vHP)

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology, Fukuoka Tokushukai Hospital, Tokushukai Medical Corporation.

Zitieren

APA

Takao, Y. (2026). Evaluation of Contrast Enhancement Uniformity and Contrast Media Optimization in Chest-to-lower Extremity CTA Using Variable Helical Pitch Scanning. Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.26-1599

Vancouver

Takao Y. Evaluation of Contrast Enhancement Uniformity and Contrast Media Optimization in Chest-to-lower Extremity CTA Using Variable Helical Pitch Scanning. Japanese Journal of Radiological Technology. 2026. doi:10.6009/jjrt.26-1599

BibTeX
@article{Takao2026,
  author = {Takao, Yuichi},
  title = {Evaluation of Contrast Enhancement Uniformity and Contrast Media Optimization in Chest-to-lower Extremity CTA Using Variable Helical Pitch Scanning},
  journal = {Japanese Journal of Radiological Technology},
  year = {2026},
  doi = {10.6009/jjrt.26-1599}
}
Kostenlos starten →