Vergleichsstudie in der Zeitschrift Japanese Journal of Radiological Technology, 2024. Verfasst von Tatsuya Kamima und 5 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Oncology Department, Cancer Institute Hospital, Japanese Foundation for Cancer Research. Hauptthemen laut MEDLINE: Phantoms, Imaging, Movement. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: We evaluated the measurement accuracy and time efficiency of the tumor respiratory motion evaluation methods using a dynamic thorax motion phantom. METHODS: A total of 12 patterns of 4DCT images with different tumor displacements and artifacts were used for the measurement. Three methods were employed to measure tumor motion. The first method was the manual delineation of the tumor on each phase CT image with a treatment planning system (RTPS [Manual]). The second method was the automatic delineation of the tumor structure by deformation and copying (RTPS [Auto]). The third method was tumor motion analysis software (Simple 4D Analysis Ver.1.3.1 [Simple 4D]; Triangle Products, Chiba, Japan). For each method, the difference between the phantom motion and the measured value was determined. RESULTS: The differences (mean±standard deviation: SD) in the superior-inferior direction for RTPS (Manual), RTPS (Auto), and Simple 4D in the without-artifact images were -0.6 mm±0.6 mm, -5.0 mm±2.2 mm, and -1.0 mm±0.0 mm, respectively. The difference in the left-right and anterior-posterior directions was within 1 mm for all methods. Furthermore, the time required for Simple 4D was shorter than for the other methods. CONCLUSION: Simple 4D showed the comparable measurement accuracy and improvement time efficiency to RTPS (Manual) and RTPS (Auto), and was useful for tumor respiratory motion analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingMovementHumansRespirationFour-Dimensional Computed TomographyThoraxMotionNeoplasmsArtifacts

Stichwörter der Autor:innen

4DCTdynamic thorax motion phantomrespiratory tumor motion

Autor:innen und Institutionen

  • Radiation Oncology Department, Cancer Institute Hospital, Japanese Foundation for Cancer Research.
  • Faculty of Medicine, University of Tsukuba.
  • Triangle Products Co Ltd.

Zitieren

APA

Kamima, T., Akashi, K., Watanabe, S., Matsubayashi, F., Tachibana, R., & Ito, Y. (2024). A Comparison of Tumor Respiratory Motion Evaluation Methods Using Dynamic Thorax Motion Phantom. Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.2024-1500

Vancouver

Kamima T, Akashi K, Watanabe S, Matsubayashi F, Tachibana R, Ito Y. A Comparison of Tumor Respiratory Motion Evaluation Methods Using Dynamic Thorax Motion Phantom. Japanese Journal of Radiological Technology. 2024. doi:10.6009/jjrt.2024-1500

BibTeX
@article{Kamima2024,
  author = {Kamima, Tatsuya and Akashi, Kana and Watanabe, Shiori and Matsubayashi, Fumiyasu and Tachibana, Rie and Ito, Yasushi},
  title = {A Comparison of Tumor Respiratory Motion Evaluation Methods Using Dynamic Thorax Motion Phantom},
  journal = {Japanese Journal of Radiological Technology},
  year = {2024},
  doi = {10.6009/jjrt.2024-1500}
}
Kostenlos starten →