EUVIMEDEUVIMED entdecken
Crossref

Evaluation of Transmitted X-ray Spectrum, Lead Equivalent, and Uniformity of Radiation Protective Clothing Made of Lead-containing and Lead-free Materials

Yuji Yano, Toshioh Fujibuchi, Hiroyuki Arakawa

Japanese Journal of Radiological Technology · 2024

DOI: 10.6009/jjrt.2024-1473 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2024. Verfasst von Yuji Yano und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Medical Quantum Science, Department of Health Science, Graduate School of Medical Science, Kyushu University. Hauptthemen laut MEDLINE: Lead, Protective Clothing, Radiation Protection. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The purpose of this study was to evaluate the protective performance of several new radiation-protective clothing and to clarify issues of quality control. METHODS: The composition of the shielding elements was analyzed using X-ray fluorescence analysis, and the energy spectrum of transmitted X-rays was measured. Furthermore, the lead equivalent and uniformity were measured from the transmitted X-ray doses according to Japanese industrial standards (JIS). Uniformity was evaluated by transmitting X-ray images of each radiation protective clothing in addition to the conventional method. RESULTS: The energy spectrum showed K-absorption edges of lead, bismuth, tin, etc., which were detected in the composition analysis. The multi-layered protective material maintained higher shielding ability at high tube voltages. In addition, X-ray images of the radiation-protective clothing showed uneven density and dots, and the differences in uniformity measurement methods and points that didn't meet the required shielding capacity were seen. CONCLUSION: The current JIS does not allow accurate evaluation of the lead equivalent and uniformity, so visual evaluation of X-ray images is important. It is necessary to establish standardized standards for quality control performed by each facility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LeadProtective ClothingRadiation ProtectionX-RaysQuality ControlSpectrometry, X-Ray EmissionRadiation Dosage

Stichwörter der Autor:innen

K-absorption edgeenergy spectrumradiation protection clothingtransmittanceuniformity

Substanzen

Lead

Autor:innen und Institutionen

  • Division of Medical Quantum Science, Department of Health Science, Graduate School of Medical Science, Kyushu University.
  • Division of Medical Quantum Science, Department of Health Science, Faculty of Medical Science, Kyushu University.

Zitieren

APA

Yano, Y., Fujibuchi, T., & Arakawa, H. (2024). Evaluation of Transmitted X-ray Spectrum, Lead Equivalent, and Uniformity of Radiation Protective Clothing Made of Lead-containing and Lead-free Materials. Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.2024-1473

Vancouver

Yano Y, Fujibuchi T, Arakawa H. Evaluation of Transmitted X-ray Spectrum, Lead Equivalent, and Uniformity of Radiation Protective Clothing Made of Lead-containing and Lead-free Materials. Japanese Journal of Radiological Technology. 2024. doi:10.6009/jjrt.2024-1473

BibTeX
@article{Yano2024,
  author = {Yano, Yuji and Fujibuchi, Toshioh and Arakawa, Hiroyuki},
  title = {Evaluation of Transmitted X-ray Spectrum, Lead Equivalent, and Uniformity of Radiation Protective Clothing Made of Lead-containing and Lead-free Materials},
  journal = {Japanese Journal of Radiological Technology},
  year = {2024},
  doi = {10.6009/jjrt.2024-1473}
}
Kostenlos starten →