Fachartikel in der Zeitschrift European Journal of Radiology, 2023. Verfasst von Alexander M König und 4 weiteren Autor:innen. Beteiligte Einrichtung: Philipps-University of Marburg, Clinic of Diagnostic and Interventional Radiology, Marburg, Germany. Electronic address: akoenig@med.uni-marburg.de. Hauptthemen laut MEDLINE: Radiation Protection, Radiation-Protective Agents. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: The objective of this study is to examine the performance of new generation protection aprons as alternative to conventional lead aprons regarding their radiation protection effectiveness. METHOD AND MATERIALS: Radiation protection aprons made of lead-containing and lead-free materials from a total of seven companies were compared. Furthermore, different lead equivalent values of 0.25, 0.35 and 0.5 mm were compared. For quantitative assessment, radiation attenuation was determined with increasing voltage in steps of 20 kV from 70 kV up to 130 kV. RESULTS: New generation aprons and conventional protection lead aprons showed a similar shielding performance at lower tube voltages below 90 kVp. When tube voltage was increased above 90 kVp, significant (p < 0.05) differences between the three apron types were observed, with conventional lead material as best shielding performer over lead composite and lead-free aprons. CONCLUSION: We observed a similar radiation protection performance between conventional lead aprons and new generation aprons at low intensity radiation workplaces, with lead aprons being dominant for all energies. Only new generation aprons of 0.5 mm thickness would adequately replace 0.25 and 0.35 mm conventional lead aprons. For healthy radiation protection, the possibility of using weight-reduced X-ray aprons is very limited.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ProtectionRadiation-Protective AgentsHumansRadiation DosageX-RaysProtective Clothing

Stichwörter der Autor:innen

Lead compositeLead freeRadiation protection

Substanzen

Radiation-Protective Agents

Autor:innen und Institutionen

  • Philipps-University of Marburg, Clinic of Diagnostic and Interventional Radiology, Marburg, Germany. Electronic address: akoenig@med.uni-marburg.de.
  • Philipps-University of Marburg, Clinic of Diagnostic and Interventional Radiology, Marburg, Germany.
  • Philipps-University of Marburg, Clinic of Diagnostic and Interventional Radiology, Marburg, Germany; University of Applied Sciences, Institute of Medical Physics and Radiation Protection, Giessen, Germany.

Zitieren

APA

König, A. M., Verbe Zoum, J., Fiebich, M., Abissi, P. W., & Mahnken, A. H. (2023). Comparison of the radiation protection effect of different radiation protection aprons made of different materials. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2023.110862

Vancouver

König AM, Verbe Zoum J, Fiebich M, Abissi PW, Mahnken AH. Comparison of the radiation protection effect of different radiation protection aprons made of different materials. European Journal of Radiology. 2023. doi:10.1016/j.ejrad.2023.110862

BibTeX
@article{Knig2023,
  author = {König, Alexander M and Verbe Zoum, Julius and Fiebich, Martin and Abissi, Pascaline-Wangechi and Mahnken, Andreas H},
  title = {Comparison of the radiation protection effect of different radiation protection aprons made of different materials},
  journal = {European Journal of Radiology},
  year = {2023},
  doi = {10.1016/j.ejrad.2023.110862}
}
Kostenlos starten →