EUVIMEDEUVIMED entdecken
Crossref

Development of Dose Calculation Application for Computed Tomography Dose Management When Facility Protocols Differ from Diagnostic Reference Level (DRL)

Yuki Kawamata, Ryuji Ikeda, Syuichi Tochihara, Masahiro Hashida, Masahiro Hatemura

Japanese Journal of Radiological Technology · 2024

DOI: 10.6009/jjrt.2024-1462 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2024. Verfasst von Yuki Kawamata und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiology, Department of Medical Technology, Kumamoto University Hospital. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiation Dosage. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: In this study, we aimed to develop an application that computes dose values resembling diagnostic reference level (DRL) conditions when disparity prevents direct dose comparisons between the national diagnostic reference levels in Japan 2020 (Japan DRLs_2020) and facility-specific computed tomography (CT) protocols. METHODS: We developed an application using the R programming language and RStudio software that computes dose values and median values based on Japan DRLs_2020 imaging conditions following extraction of necessary information for dose calculations from the Radiation Dose Structured Report (RDSR) and Digital Imaging and Communications in Medicine (DICOM) tags. To ensure a user-friendly experience, we used the Shiny package to develop a graphical user interface that enables the application to operate seamlessly in web browsers. RESULTS: The developed application successfully facilitated the calculation of dose and median values that aligned with the Japan DRLs_2020 for protocols whose imaging range and acquisition timing differed from those of the Japan DRLs_2020. CONCLUSION: By calculating dose values that align with DRL conditions, our application contributes to the implementation and optimization of dose management in CT for facilities that use diverse imaging protocols.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedRadiation DosageHumansDiagnostic Reference LevelsSoftwareJapan

Stichwörter der Autor:innen

Rdiagnostic reference level (DRL)digital imaging and communications in medicine (DICOM)dose managementradiation dose structured report (RDSR)

Autor:innen und Institutionen

  • Division of Radiology, Department of Medical Technology, Kumamoto University Hospital.
  • Department of Radiological Technology, Faculty of Fukuoka Medical Technology, Teikyo University.

Zitieren

APA

Kawamata, Y., Ikeda, R., Tochihara, S., Hashida, M., & Hatemura, M. (2024). Development of Dose Calculation Application for Computed Tomography Dose Management When Facility Protocols Differ from Diagnostic Reference Level (DRL). Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.2024-1462

Vancouver

Kawamata Y, Ikeda R, Tochihara S, Hashida M, Hatemura M. Development of Dose Calculation Application for Computed Tomography Dose Management When Facility Protocols Differ from Diagnostic Reference Level (DRL). Japanese Journal of Radiological Technology. 2024. doi:10.6009/jjrt.2024-1462

BibTeX
@article{Kawamata2024,
  author = {Kawamata, Yuki and Ikeda, Ryuji and Tochihara, Syuichi and Hashida, Masahiro and Hatemura, Masahiro},
  title = {Development of Dose Calculation Application for Computed Tomography Dose Management When Facility Protocols Differ from Diagnostic Reference Level (DRL)},
  journal = {Japanese Journal of Radiological Technology},
  year = {2024},
  doi = {10.6009/jjrt.2024-1462}
}
Kostenlos starten →