EUVIMEDEUVIMED entdecken
Crossref

Data analysis of average glandular dose in mammography toward revision of the diagnostic reference level of Japan

Toru Negishi, Yusuke Koba, Kiyomitsu Shinsho, Daisuke Fujise, Masahiro Sai, Hiroko Nishide

Radiological Physics and Technology · 2024

DOI: 10.1007/s12194-024-00823-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiological Physics and Technology, 2024. Verfasst von Toru Negishi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan. Hauptthemen laut MEDLINE: Mammography, Radiation Dosage, Diagnostic Reference Levels. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diagnostic reference level (DRL) for mammography for 2015 and 2020 has been published by J-RIME. More new dose studies are needed to revise the next DRL. In preparation for the next revision of the DRL for mammography, this study investigated data from the Japan Central Organization on Quality Assurance of Breast Cancer Screening on the mean average glandular dose (AGD) for institutional image accreditation in 2019-2023 and the relationship between the average at eligible institutions to date and the type of breast X-ray system. The 95th percentile values of the AGD distributions for the Computed Radiography (CR) and Flat Panel Detector (FPD) systems were 2.5 mGy and 2.0 mGy, respectively. Moreover, it is assumed that AGD is decreasing due to the spread of FPD systems, and it is expected that the further spread of FPD systems and systems with W/Rh target/filter will reduce AGD in future.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MammographyRadiation DosageDiagnostic Reference LevelsJapanHumansFemaleData AnalysisBreastBreast Neoplasms

Stichwörter der Autor:innen

Average glandular doseDiagnostic reference level (DRL)Mammography

Autor:innen und Institutionen

  • Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan.
  • Institute of Radiological Sciences, National Institutes for Quantum Science and Technology, Chiba, Japan. koba.yusuke@qst.go.jp.
  • Department of Information Technology and Management, National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Japan Central Organization On Quality Assurance of Breast Cancer Screening, Nagoya, Japan.
  • Department of Radiology, Tohoku University Hospital, Sendai, Japan.
  • Department of Radiological Technology, School of Health Sciences, Gifu University of Medical Science, Seki, Japan.

Zitieren

APA

Negishi, T., Koba, Y., Shinsho, K., Fujise, D., Sai, M., & Nishide, H. (2024). Data analysis of average glandular dose in mammography toward revision of the diagnostic reference level of Japan. Radiological Physics and Technology. https://doi.org/10.1007/s12194-024-00823-9

Vancouver

Negishi T, Koba Y, Shinsho K, Fujise D, Sai M, Nishide H. Data analysis of average glandular dose in mammography toward revision of the diagnostic reference level of Japan. Radiological Physics and Technology. 2024. doi:10.1007/s12194-024-00823-9

BibTeX
@article{Negishi2024,
  author = {Negishi, Toru and Koba, Yusuke and Shinsho, Kiyomitsu and Fujise, Daisuke and Sai, Masahiro and Nishide, Hiroko},
  title = {Data analysis of average glandular dose in mammography toward revision of the diagnostic reference level of Japan},
  journal = {Radiological Physics and Technology},
  year = {2024},
  doi = {10.1007/s12194-024-00823-9}
}
Kostenlos starten →