Vision Transformer Reconstruction for Super-Resolution and Artifact Reduction in 1.5-Tesla Fast-Spin-Echo Pelvic MRI: A Diagnostic-Accuracy Study
Sriwijaya Journal of Radiology and Imaging Research · 07.08.2026 · 4 (1) · 16-24
DOI: 10.59345/sjrir.v4i1.322 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sriwijaya Journal of Radiology and Imaging Research, online erschienen am 07.08.2026. Verfasst von Muhammad Rusli und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
Fast-spin-echo (FSE) MRI is the reference modality for pelvic evaluation, but high-resolution acquisition is slow and motion-prone. Deep-learning reconstruction may recover diagnostic quality from short, motion-tolerant acquisitions, yet most evidence relies on image-similarity indices rather than radiologist performance. We validated a Vision-Transformer (ViT) reconstruction for simultaneous super-resolution and motion-artifact reduction in 1.5-Tesla T2-weighted FSE pelvic MRI.
Methods
In this retrospective diagnostic-accuracy study (STARD 2015) at a tertiary hospital in Palembang, Indonesia, 450 examinations (development n=360; test n=90) were analysed. A U-shaped shifted-window ViT reconstructed high-resolution images from retrospectively degraded low-resolution/motion-corrupted inputs. Two blinded radiologists scored each test case under native low-resolution, UNet- and ViT-reconstructed conditions against a histopathology/expert-consensus reference standard. Sensitivity, specificity, predictive values, AUC, likelihood ratios (95% CI), inter-reader kappa, DeLong and McNemar tests, and multivariable logistic regression were computed.
Results
Target prevalence was 53.3%. ViT reconstruction achieved sensitivity 93.8% (95% CI 83.2–97.9), specificity 88.1% (75.0–94.8), AUC 0.943 (0.894–0.992), LR+ 7.87 and LR− 0.071, versus AUC 0.881 (UNet) and 0.751 (low-resolution); ViT vs low-resolution DeLong p
Zitieren
APA
Rusli, M., Suryani, F., & Montesinos, D. (2026). Vision Transformer Reconstruction for Super-Resolution and Artifact Reduction in 1.5-Tesla Fast-Spin-Echo Pelvic MRI: A Diagnostic-Accuracy Study. Sriwijaya Journal of Radiology and Imaging Research, 4(1), 16-24. https://doi.org/10.59345/sjrir.v4i1.322
Vancouver
Rusli M, Suryani F, Montesinos D. Vision Transformer Reconstruction for Super-Resolution and Artifact Reduction in 1.5-Tesla Fast-Spin-Echo Pelvic MRI: A Diagnostic-Accuracy Study. Sriwijaya Journal of Radiology and Imaging Research. 2026;4(1):16-24. doi:10.59345/sjrir.v4i1.322
BibTeX
@article{Rusli2026,
author = {Rusli, Muhammad and Suryani, Febria and Montesinos, Desiree},
title = {Vision Transformer Reconstruction for Super-Resolution and Artifact Reduction in 1.5-Tesla Fast-Spin-Echo Pelvic MRI: A Diagnostic-Accuracy Study},
journal = {Sriwijaya Journal of Radiology and Imaging Research},
year = {2026},
volume = {4},
number = {1},
pages = {16--24},
doi = {10.59345/sjrir.v4i1.322}
}
EUVIMED