EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Imdose Phantom Development For Quality Assurance And Control In Computed Tomography Imaging Study Of Image Quality And Dosage Assessment

Djuli Pontjowijono, Donny Kristanto Mulyantoro, Rini Indrati

International Journal of Social Health · 2023

DOI: 10.58860/ijsh.v2i10.105 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Social Health, 2023. Verfasst von Djuli Pontjowijono und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

C.T. has made a great contribution to detecting and diagnosing patients' diseases. C.T., before being applied to patients, must pass quality assurance and control with phantom. However, the availability of phantoms is still minimal because of their high price. His study aims to create and evaluate cylindrical phantoms for quality assurance and control procedures based on image quality and dose parameters. The research method involves creating an image-quality phantom design that references the CatPhan phantom using Sketchup. The results show that the phantom image provides results from the standard phantom; the SNR, CNR, MTF, noise, and MTF values of the ImDose phantom are still within the standard phantom criteria. Based on statistical tests, the image quality of SNR, CNR, MTF, NPS, and noise is not statistically significantly different from the standard phantom (p > 0.05). The uniformity value still needs to be improved because it has a significant difference from the standard phantom with an ap value

Zitieren

APA

Pontjowijono, D., Mulyantoro, D. K., & Indrati, R. (2023). Imdose Phantom Development For Quality Assurance And Control In Computed Tomography Imaging Study Of Image Quality And Dosage Assessment. International Journal of Social Health. https://doi.org/10.58860/ijsh.v2i10.105

Vancouver

Pontjowijono D, Mulyantoro DK, Indrati R. Imdose Phantom Development For Quality Assurance And Control In Computed Tomography Imaging Study Of Image Quality And Dosage Assessment. International Journal of Social Health. 2023. doi:10.58860/ijsh.v2i10.105

BibTeX
@article{Pontjowijono2023,
  author = {Pontjowijono, Djuli and Mulyantoro, Donny Kristanto and Indrati, Rini},
  title = {Imdose Phantom Development For Quality Assurance And Control In Computed Tomography Imaging Study Of Image Quality And Dosage Assessment},
  journal = {International Journal of Social Health},
  year = {2023},
  doi = {10.58860/ijsh.v2i10.105}
}
Kostenlos starten →