Comparative Evaluation of Marginal Fit Between CAD/CAM and Conventional Metal-Ceramic Crowns
OTS Canadian Journal · 2025
DOI: 10.58840/b5gdcv24 ↗Kurz gefasst
Fachartikel in der Zeitschrift OTS Canadian Journal, 2025. Verfasst von Dr. Shilan H. Fatah. Die Arbeit wurde bisher 1-mal zitiert (Crossref).
Abstract (Originalsprache)
Objective
This study aimed to evaluate and compare the marginal fit of metal-ceramic crowns fabricated using computer-aided design/computer- aided manufacturing (CAD/CAM) technology and the conventional lost- wax casting technique.
Methods
An in-vitro experimental design was employed using 40 standardized metal-ceramic crowns, equally divided into two groups: Group A (CAD/CAM) and Group B (Conventional). All crowns were fabricated for identical typodont molar preparations. Marginal adaptation was assessed using the silicone replica technique and examined under a stereomicroscope at 40× magnification. Data were analyzed using SPSS v25, with statistical significance set at p < 0.05.
Results
The CAD/CAM group showed a mean marginal gap of 54.2 ± 8.5 µm, whereas the conventional group exhibited 89.7 ± 12.4 µm. The independent t-test confirmed a statistically significant difference (p
Zitieren
APA
Fatah, D. S. H. (2025). Comparative Evaluation of Marginal Fit Between CAD/CAM and Conventional Metal-Ceramic Crowns. OTS Canadian Journal. https://doi.org/10.58840/b5gdcv24
Vancouver
Fatah DSH. Comparative Evaluation of Marginal Fit Between CAD/CAM and Conventional Metal-Ceramic Crowns. OTS Canadian Journal. 2025. doi:10.58840/b5gdcv24
BibTeX
@article{Fatah2025,
author = {Fatah, Dr. Shilan H.},
title = {Comparative Evaluation of Marginal Fit Between CAD/CAM and Conventional Metal-Ceramic Crowns},
journal = {OTS Canadian Journal},
year = {2025},
doi = {10.58840/b5gdcv24}
}