Evaluation of the Apical Microleakage using Zinc Oxide Eugenol via three Different Obturation Techniques (Reamer, Tuberculin syringe and Modified Disposable Syringe) in Primary Teeth An In Vitro Study
journal of medical and oral biosciences · 01.06.2026 · 3 (2) · 39-54
DOI: 10.58564/jmob.156 ↗Kurz gefasst
Fachartikel in der Zeitschrift journal of medical and oral biosciences, online erschienen am 30.05.2026. Verfasst von Dhuha Najm Abdulhussein.
Abstract (Originalsprache)
Maintenance of primary dentition is important for a preventing arch-length discrepancy. Therefore, successful root canal treatment is important for keeping such teeth until natural exfoliation occurs. This research was conducted to quantitatively assess the sealing ability and time taken for obturation with Zinc Oxide Eugenol via different three obturation methods. Thirty-six extracted anterior primary teeth samples were included in this study. Canals were prepared by K-files (15 45) and obturated by ZOE. The teeth were divided randomly into three experimental groups (n=12), randomly as follows: Group I (Modified Disposable Syringe), Group II (Reamer Technique) and Group III (Tuberculin Syringe). The dye extraction technique was utilized for microleakage evaluation, and obturation time was recorded for each sample. All results were statistical analyze, and P < 0.05 was considered to be significant. The mean microleakage of the modified disposable syringe group was lower than microleakage amounts in the tuberculin syringe and reamer groups with no statistical difference (p > 0.05). In terms of obturation duration, using the modified disposable syringe technique, the time was less than the tuberculin group with no statistical significance difference, and less compared to that of the reamer technique group with a statistical significance difference (p < 0.05). In conclusion, modified disposable syringe that used in this study was the most acceptable obturation method when ZOE was used to obturate the primary teeth. It has a better apical seal and saves up on chair time, which is of high importance in successful pediatric practice.
Zitieren
APA
Abdulhussein, D. N. (2026). Evaluation of the Apical Microleakage using Zinc Oxide Eugenol via three Different Obturation Techniques (Reamer, Tuberculin syringe and Modified Disposable Syringe) in Primary Teeth An In Vitro Study. journal of medical and oral biosciences, 3(2), 39-54. https://doi.org/10.58564/jmob.156
Vancouver
Abdulhussein DN. Evaluation of the Apical Microleakage using Zinc Oxide Eugenol via three Different Obturation Techniques (Reamer, Tuberculin syringe and Modified Disposable Syringe) in Primary Teeth An In Vitro Study. journal of medical and oral biosciences. 2026;3(2):39-54. doi:10.58564/jmob.156
BibTeX
@article{Abdulhussein2026,
author = {Abdulhussein, Dhuha Najm},
title = {Evaluation of the Apical Microleakage using Zinc Oxide Eugenol via three Different Obturation Techniques (Reamer, Tuberculin syringe and Modified Disposable Syringe) in Primary Teeth An In Vitro Study},
journal = {journal of medical and oral biosciences},
year = {2026},
volume = {3},
number = {2},
pages = {39--54},
doi = {10.58564/jmob.156}
}
EUVIMED