Advanced Corrosion Monitoring System for Existing Reinforced Concrete Structures Repaired with Sacrificial Anodes
e-Journal of Nondestructive Testing · 2026-08 · 31 (8)
DOI: 10.58286/34031 ↗Kurz gefasst
Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-08. Verfasst von Josep Ramon Lliso ferrando und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Corrosion of reinforcing steel remains one of the leading causes of deterioration, loss of serviceability, and premature failure in reinforced concrete structures. Its impact is becoming increasingly critical as a large proportion of existing infrastructure approaches or exceeds its original design life, with many elements already exhibiting significant damage. Although numerous sensing technologies have been developed to improve the assessment and monitoring of corrosion processes, most systems are conceived for installation during construction, which greatly limits their applicability to existing structures—particularly those that have undergone repair interventions or incorporate sacrificial anodes. This limitation is especially critical today, given the growing number of structures being repaired and the frequent lack of reliable verification regarding the effectiveness of such interventions. This work presents the adaptation and validation of a corrosion monitoring system originally designed for new construction and previously demonstrated to be reliable in real structures, including those produced with UHPFRC. The system is based on a robust and well-established electrochemical technique, whose reproducibility and stability have been verified in multiple field applications. Building on this validated foundation, the system has been re-engineered to allow non-intrusive installation in existing reinforced concrete elements, including those that have been repaired using sacrificial anodes. The methodological programme focused on evaluating the system’s performance under conditions representative of real deterioration and repair scenarios. Several reinforced concrete slabs were fabricated and intentionally contaminated with chlorides to induce active corrosion. Subsequently, sacrificial anodes were installed following standard repair practice. The adapted monitoring system was then employed to assess both corrosion activity and the performance of the repair. Measurements included continuous corrosion rate monitoring, temporal evolution of electrochemical potentials, and assessment of current flows between protected and unprotected areas. In addition, the system was used to quantify the consumption behaviour of the sacrificial anodes, enabling the estimation of their effective service life. Special emphasis was placed on the system’s ability to detect localised corrosion processes, differentiate between galvanically protected and unprotected zones, and maintain signal stability despite heterogeneous moisture and chloride profiles. The results demonstrate that the adapted system provides consistent, spatially resolved information on reinforcement corrosion and on the performance of sacrificial anodes throughout their service life. The device proved capable of identifying areas where protection may be insufficient and of tracking the depletion of anodes with a level of resolution not typically available in current monitoring approaches. These findings confirm that the system constitutes a practical and effective tool for post-repair assessment, offering robust data to support maintenance planning and long-term durability management. Given the increasing prevalence of corrosion-related problems in existing infrastructure, the availability of such a monitoring solution holds particular relevance for ensuring effective repairs, optimising intervention strategies, and extending the service life of the reinforced concrete stock.
Zitieren
APA
ferrando, J. R. L., Martínez-ibernón, A., Gandía-Romero, J. M., Gasch, I., tro, R. V., & Valcuende, M. (2026). Advanced Corrosion Monitoring System for Existing Reinforced Concrete Structures Repaired with Sacrificial Anodes. e-Journal of Nondestructive Testing, 31(8). https://doi.org/10.58286/34031
Vancouver
ferrando JRL, Martínez-ibernón A, Gandía-Romero JM, Gasch I, tro RV, Valcuende M. Advanced Corrosion Monitoring System for Existing Reinforced Concrete Structures Repaired with Sacrificial Anodes. e-Journal of Nondestructive Testing. 2026;31(8). doi:10.58286/34031
BibTeX
@article{ferrando2026,
author = {ferrando, Josep Ramon Lliso and Martínez-ibernón, Ana and Gandía-Romero, José Manuel and Gasch, Isabel and tro, Roberto Vengut and Valcuende, Manuel},
title = {Advanced Corrosion Monitoring System for Existing Reinforced Concrete Structures Repaired with Sacrificial Anodes},
journal = {e-Journal of Nondestructive Testing},
year = {2026},
volume = {31},
number = {8},
doi = {10.58286/34031}
}
EUVIMED