Comparative Evaluation of Conventional and Advanced NDE for Rebar Corrosion Monitoring in Concrete Structures
e-Journal of Nondestructive Testing · 2026-07 · 31 (7)
DOI: 10.58286/33979 ↗Kurz gefasst
Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-07. Verfasst von Krassimir Stoev und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Half-cell potential is a non-destructive technique that can only monitor the corrosion rate of carbon steel reinforcement bars (rebars). In this study, half-cell potential was used together with Acoustic Emission (AE) and Ground Penetrating Radar (GPR) techniques to quantify the level of corrosion on the rebar. Five concrete blocks were prepared with embedded 16 mm rebars for accelerated corrosion testing. Three of the blocks were subjected to accelerated corrosion in a 5% saline solution, while the other two concrete blocks were used as control samples, with one sample placed in potable water, and the other was left in the air. The three test blocks underwent accelerated corrosion for approximately 5 months, with measurements continuing for over 1 year. An AE system continuously monitored the samples, whereas half-cell potential measurements with the GalvaPulse and iCOR instruments were performed weekly, with GPR data collected bi-weekly. The AE system detected corrosion-related microcrack formation signals across all exposed sample blocks. A new methodology and corresponding software were developed to process the GPR data for rebar corrosion monitoring. The GPR analysis focused on the rebar’s reflection peak, as it offered a stable and reproducible monitoring point. The accelerated corrosion samples exhibited distinct GPR signal trends, clearly separating them from control blocks. Monitoring a single rebar-aligned trace proved to be the most reliable approach for identifying corrosion-related changes. The presentation will discuss the experiment and present the results from data processing of the half-cell potentials, AE and GPR data from this investigation.
Zitieren
APA
Stoev, K., Simova, E., & Qureshi, T. (2026). Comparative Evaluation of Conventional and Advanced NDE for Rebar Corrosion Monitoring in Concrete Structures. e-Journal of Nondestructive Testing, 31(7). https://doi.org/10.58286/33979
Vancouver
Stoev K, Simova E, Qureshi T. Comparative Evaluation of Conventional and Advanced NDE for Rebar Corrosion Monitoring in Concrete Structures. e-Journal of Nondestructive Testing. 2026;31(7). doi:10.58286/33979
BibTeX
@article{Stoev2026,
author = {Stoev, Krassimir and Simova, Eli and Qureshi, Tanvir},
title = {Comparative Evaluation of Conventional and Advanced NDE for Rebar Corrosion Monitoring in Concrete Structures},
journal = {e-Journal of Nondestructive Testing},
year = {2026},
volume = {31},
number = {7},
doi = {10.58286/33979}
}
EUVIMED