Abstract (Originalsprache)

Strain gauges are widely used in Structural Health Monitoring (SHM) systems, due to their low cost and the extensive research that has been conducted on them. However, their highly localised measurements mean that many units are required. Measuring each strain gauge individually requires many measurement channels and extensive cabling, which can lead to a lot of manual labour and high costs. SHM systems are becoming increasingly relevant due to their potential cost and weight savings. At the same time, the amount of measurement data needs to be reduced. The aim of this work is to develop a measuring system that can cover a large area with a small number of measuring points and, consequently, a small amount of measuring data. It must be demonstrated that the measuring system can distinguish between different types of load and damage. In order to demonstrate the benefits of reducing cables and data while ensuring that a single crack influences only a single strain gauge, a network of seven strain gauges has been chosen. Rather than measuring the strain of these strain gauges individually, they are interconnected according to the setup shown in Figure 1, forming a strain gauge network. Resistances are measured between the points (1-3), (1-4), (1-5) and (1-6). First, an analytical calculation is conducted to determine the minimum number of measurement channels required for each level of SHM. It was found that four measurement channels are sufficient for load monitoring, as well as for detecting, localising and classifying a single crack in a network of seven strain gauges. While this may not seem like a significant reduction, measuring every strain gauge in larger networks would result in a substantial amount of cabling. An experiment is conducted on a four-point bending beam. Highly sensitive resistance measurements were used to verify the analytical results. After tests are performed to verify the load monitoring results, a crack is induced in the middle of the beam, to demonstrate the network’s SHM capabilities. Analytical calculations show that load monitoring and detection of different damage locations and sizes can be conducted using fewer measurement channels than strain gauges. Experimental results from a four-point bending test confirm these calculations. Future work will involve testing larger networks, as well as entire coatings, with the aim of eliminating the need for strain gauges and manual cabling entirely.

Zitieren

APA

Dietz, L., & Schröder, K. (2026). Damage Detection in Strain Gauge Networks Using Reduced Measurement Outputs. e-Journal of Nondestructive Testing, 31(8). https://doi.org/10.58286/34016

Vancouver

Dietz L, Schröder K. Damage Detection in Strain Gauge Networks Using Reduced Measurement Outputs. e-Journal of Nondestructive Testing. 2026;31(8). doi:10.58286/34016

BibTeX
@article{Dietz2026,
  author = {Dietz, Lucas and Schröder, Kai-Uwe},
  title = {Damage Detection in Strain Gauge Networks Using Reduced Measurement Outputs},
  journal = {e-Journal of Nondestructive Testing},
  year = {2026},
  volume = {31},
  number = {8},
  doi = {10.58286/34016}
}
Kostenlos starten →