CIVA confirms L-mode in SH Shear wave generation
e-Journal of Nondestructive Testing · 2026-07 · 31 (7)
DOI: 10.58286/33983 ↗At a glance
Journal article in e-Journal of Nondestructive Testing, 2026-07. Written by Edward Ginzel.
Abstract (original language)
Normal incident shear, or SH wave probes are often used to assess shear wave acoustic velocities. These have been particularly useful when dealing with anisotropic steels to assess the degree of birefringence. Another application often touted for their use is ultrasonic testing of austenitic steels where it is considered useful since they are promoted as not mode-converting upon reflection. In spite of the promotion as having no mode conversion to compression waves, anyone that has looked closely at the A-scan when assessing acoustic velocities has seen early-arrival signals that are clearly the result of a compression mode being present. This paper examines the presence of these signals using photoelastic imaging and uses CIVA simulation software to confirm them.
Cite
APA
Ginzel, E. (2026). CIVA confirms L-mode in SH Shear wave generation. e-Journal of Nondestructive Testing, 31(7). https://doi.org/10.58286/33983
Vancouver
Ginzel E. CIVA confirms L-mode in SH Shear wave generation. e-Journal of Nondestructive Testing. 2026;31(7). doi:10.58286/33983
BibTeX
@article{Ginzel2026,
author = {Ginzel, Edward},
title = {CIVA confirms L-mode in SH Shear wave generation},
journal = {e-Journal of Nondestructive Testing},
year = {2026},
volume = {31},
number = {7},
doi = {10.58286/33983}
}
EUVIMED