Corrosion state assessment of steel in infrastructures during maintenance operations by RFID battery-less corrosion sensors
e-Journal of Nondestructive Testing · 2026-08 · 31 (8)
DOI: 10.58286/33875 ↗At a glance
Journal article in e-Journal of Nondestructive Testing, 2026-08. Written by Stephane Rioual and 3 co-authors.
Abstract (original language)
The service life of reinforced and prestressed concrete infrastructures, such as bridges or harbours, is highly dependent on the corrosion resistance of steel. Indeed, in marine environments, carbonation and chloride penetration from the external environment are known to initiate corrosion processes of steel leading subsequently to the weakening of the infrastructure, and eventually to its collapse. A striking example is the collapse of the Morandi bridge at Genova. Traditional corrosion detection methods, such as visual inspections, are time-consuming and costly, and does not allow an early detection of corrosion since steel material is, most of the time, inaccessible either placed in concrete for reinforced concrete or in High-Density Polyethylene (HDPE) ducts for prestressed structures. Recently, Radio Frequency Identification (RFID) technology was proposed as a new method that can be used for corrosion detection. Passive RFID corrosion sensors are particularly attractive because of their small dimensions, their cheapness and possibility to work wirelessly. Furthermore, the absence of batteries and cables facilitates their integration in concrete during construction or maintenance/repair operations and ensures a long life-service. In particular, in an European project dedicated to the cultural heritage sector, we proposed an UHF-RFID sensor based on the coupling between an RFID antenna and an additional sensitive metallic layer exposed to atmospheric corrosion [1]. The principle is simple: during corrosion, the thickness of the thin metal sheet decreases leading to an increase of its electrical resistance and hence to a variation of properties of the coupled antenna. Monitoring the variation of power received by the RFID reader, namely the RSSI factor, provides thus valuable information on the residual thickness of the sensitive metallic layer. Recently, this method was proposed to improved maintenance operations of prestressed bridges [2] and harbours [3]. At the EWSHM conference, recent developments of such technology will be presented and discussed. In particular, a focus will be made on the durability of these embedded battery-less sensors in infrastructures. This is obviously a crucial question since these sensors are expected to monitor steel corrosion over several decades. References 1. I. El Masri, B. Lescop, P. Talbot, G. Nguyen Vien, J. Becker, D. Thierry, and S. Rioual, “Development of a RFID sensitive tag dedicated to the monitoring of the environmental corrosiveness for indoor applications,”Sensors and Actuators B: Chemical, 322, 128602, 2020. 2. L. Gaillet, C. Sarr, Y. Falaise, S. Chataigner, P. Talbot, B. Lescop, and S. Rioual, “RFID sensor development for corrosion monitoring in bridges cables,” Nondestructive Testing and Evaluation, 1–19, 2025. 3. S. Rioual, B. Lescop, P. Talbot, C. Vo and T. L. Ngoc, "Improving Harbour Infrastructure Inspections by Autonomous Corrosion Sensors Interrogated by Drones," OCEANS 2025 Brest, BREST, France, 2025.
Cite
APA
Rioual, S., Lescop, B., Mugabo, B., & Talbot, P. (2026). Corrosion state assessment of steel in infrastructures during maintenance operations by RFID battery-less corrosion sensors. e-Journal of Nondestructive Testing, 31(8). https://doi.org/10.58286/33875
Vancouver
Rioual S, Lescop B, Mugabo B, Talbot P. Corrosion state assessment of steel in infrastructures during maintenance operations by RFID battery-less corrosion sensors. e-Journal of Nondestructive Testing. 2026;31(8). doi:10.58286/33875
BibTeX
@article{Rioual2026,
author = {Rioual, Stephane and Lescop, Benoit and Mugabo, Benjamin and Talbot, Philippe},
title = {Corrosion state assessment of steel in infrastructures during maintenance operations by RFID battery-less corrosion sensors},
journal = {e-Journal of Nondestructive Testing},
year = {2026},
volume = {31},
number = {8},
doi = {10.58286/33875}
}
EUVIMED