EUVIMEDEUVIMED entdecken
Crossref

Comparative Temperature-Dependent Performance of Hard, Soft, and Very-Soft PZT Transducers for Guided Wave Structural Health Monitoring

Shankar Galiana, Bhooshit Patel, Maria Moix-Bonet, Alexander FISCHER, Peter Wierach

e-Journal of Nondestructive Testing · 2026-08 · 31 (8)

DOI: 10.58286/33837 ↗

Kurz gefasst

Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-08. Verfasst von Shankar Galiana und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Structural Health Monitoring (SHM) has emerged as a candidate approach for cryogenic hydrogen systems, reusable launch vehicles, and space structures operating under extreme environmental and operational conditions (EOCs). Reliable SHM across such conditions requires both compensation of EOC influences and stable transducer behavior over the full temperature range. In guided wave (GW)-based SHM, this is particularly critical because of the strong temperature dependence of piezoceramic materials. This work presents a comparative study of hard (HRD-PZT), soft (SFT-PZT) and very-soft (VSF-PZT) Lead Zirconate-Titanate transducers from approximately 27 K to 353 K. Electromechanical impedance (EMI) measurements on unbonded discs in a helium cryostat and in a climate chamber were used to extract the temperature-dependent d31 coefficient via the radial-mode procedure. Guided wave experiments were performed on an instrumented copper plate in the same cryostat (40–290 K) and on aluminum plates in a climate chamber (233–353 K), enabling a cross-substrate consistency check. At room temperature, the EMI measurements reproduce the expected VSF > SFT > HRD ordering, and the GW measurements show the same observed ordering. At cryogenic temperatures the EMI hierarchy is preserved, VSF-PZT retains the largest absolute d31, but the GW amplitude hierarchy reverses: HRD-PZT delivers the largest A0- and S0-mode amplitudes below approximately 220 K. GW amplitudes are well described by a two-stage linear trend for HRD-PZT and by a sigmoidal trend for SFT- and VSF-PZT. In the climate-chamber range, a non-monotonic behaviour with a maximum near 310–320 K is consistent with softening of the structural adhesive near its glass-transition temperature. These results highlight that transducer selection for cryogenic SHM cannot rely on room-temperature datasheet values alone and must combine intrinsic piezoelectric properties with the temperature-dependent electromechanical coupling to the host structure

Zitieren

APA

Galiana, S., Patel, B., Moix-Bonet, M., FISCHER, A., & Wierach, P. (2026). Comparative Temperature-Dependent Performance of Hard, Soft, and Very-Soft PZT Transducers for Guided Wave Structural Health Monitoring. e-Journal of Nondestructive Testing, 31(8). https://doi.org/10.58286/33837

Vancouver

Galiana S, Patel B, Moix-Bonet M, FISCHER A, Wierach P. Comparative Temperature-Dependent Performance of Hard, Soft, and Very-Soft PZT Transducers for Guided Wave Structural Health Monitoring. e-Journal of Nondestructive Testing. 2026;31(8). doi:10.58286/33837

BibTeX
@article{Galiana2026,
  author = {Galiana, Shankar and Patel, Bhooshit and Moix-Bonet, Maria and FISCHER, Alexander and Wierach, Peter},
  title = {Comparative Temperature-Dependent Performance of Hard, Soft, and Very-Soft PZT Transducers for Guided Wave Structural Health Monitoring},
  journal = {e-Journal of Nondestructive Testing},
  year = {2026},
  volume = {31},
  number = {8},
  doi = {10.58286/33837}
}
Kostenlos starten →