EUVIMEDObjevte EUVIMED
Crossref

Piezoelectric capacitance measurements for structural health monitoring

Marta Berardengo, Marco Mercato, Marcello Vanali, Stefano Manzoni

e-Journal of Nondestructive Testing · 2026-08 · 31 (8)

DOI: 10.58286/33800 ↗

At a glance

Journal article in e-Journal of Nondestructive Testing, 2026-08. Written by Marta Berardengo and 3 co-authors.

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

In structures equipped with piezoelectric transducers, the quantification of the efficiency of the energy conversion between mechanical and electrical domain (and vice versa) was already demonstrated to be a reliable feature for determining the presence of a structural damage. This monitoring approach was demonstrated not only to be sensitive to damage presence, but also to its location. Furthermore, low sensitivity to temperature was demonstrated analytically and through experimental tests. The efficiency of energy conversion is determined by means of vibration measurements to derive the value of the modal electro-mechanical coupling coefficient, which is the damage feature employed to calculate damage indexes. For a given piezoelectric transducer (either patch or stack) attached to a structure, the modal electro-mechanical coupling coefficient is estimated at a given eigenmode by deriving the corresponding eigenfrequencies with the transducer short- and open-circuited, implying the need of performing two operational modal analyses in two different configurations. It is possible to demonstrate that method sensitivity to damage is similar to those of methods based on estimation of either eigenfrequencies or mode shapes, but with the following advantages: the modal electro-mechanical coupling coefficient is less sensitive to temperature compared to eigenfrequencies, and its value is correlated to mode shape even if its estimation does not require any dense measurement mesh (which instead occurs for mode shape estimation). Nevertheless, in some cases, the estimation of this damage feature with vibration measurements can be challenging because of different reasons, such as, e.g., non sufficient external excitation to the system, low values of the modal electro-mechanical coupling coefficient which makes its estimation uncertain and implies the need of shunting the piezoelectric elements with tailored electrical impedances for improving estimation, significant temperature variations during the modal tests when they are long. The present paper aims at showing that similar damage indexes can be estimated also by measuring capacitance trend as function of frequency for each piezoelectric element in the structure. This allows monitoring the structure by means of quick tests not affected by environmental changes, without any need of vibration measurements and addition of external electric circuits used to shunt the piezoelectric elements, with significant simplification of the estimation procedure. Three different damage indexes are proposed, evidencing which of them are the most reliable for detecting the presence of the damage and getting information about its location. The method and the indexes are studied through numerical analyses and validated by means of an experimental campaign on tailored set-ups.

Cite

APA

Berardengo, M., Mercato, M., Vanali, M., & Manzoni, S. (2026). Piezoelectric capacitance measurements for structural health monitoring. e-Journal of Nondestructive Testing, 31(8). https://doi.org/10.58286/33800

Vancouver

Berardengo M, Mercato M, Vanali M, Manzoni S. Piezoelectric capacitance measurements for structural health monitoring. e-Journal of Nondestructive Testing. 2026;31(8). doi:10.58286/33800

BibTeX
@article{Berardengo2026,
  author = {Berardengo, Marta and Mercato, Marco and Vanali, Marcello and Manzoni, Stefano},
  title = {Piezoelectric capacitance measurements for structural health monitoring},
  journal = {e-Journal of Nondestructive Testing},
  year = {2026},
  volume = {31},
  number = {8},
  doi = {10.58286/33800}
}
Start for free →