Magnetic Testing of coated components with high Dry Film Thickness (> 50 µm) using AC and DC Electromagnetic Yokes

Erik Del Forno, Nicola Marasco, Stefano Verdino, Riccardo D'Amico, Dario Tonali, Enrico Vignati

e-Journal of Nondestructive Testing · 2026-07 · 31 (7)

DOI: 10.58286/33269 ↗

At a glance

Journal article in e-Journal of Nondestructive Testing, 2026-07. Written by Erik Del Forno and 5 co-authors.

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

Non-Destructive Testing (NDT) is essential for assessing the structural integrity of components subjected to in-service stresses. When such components are exposed to corrosive environments, the application of a protective coating becomes equally critical. Nevertheless, these two requirements often conflict, particularly in the case of Magnetic Testing (MT) using a portable AC yoke, which is conventionally performed on uncoated surfaces to ensure optimal testing conditions. Nevertheless, production constraints may sometimes dictate that inspection be performed after the painting process. This study aims to experimentally assess the efficacy and accuracy of MT when the Dry Film Thickness (DFT) of the protective coating exceeds the limits specified by reference standards,considering that many industrial painting cycles frequently result in a DFT greater than 200 µm.

Cite

APA

Forno, E. D., Marasco, N., Verdino, S., D'Amico, R., Tonali, D., & Vignati, E. (2026). Magnetic Testing of coated components with high Dry Film Thickness (> 50 µm) using AC and DC Electromagnetic Yokes. e-Journal of Nondestructive Testing, 31(7). https://doi.org/10.58286/33269

Vancouver

Forno ED, Marasco N, Verdino S, D'Amico R, Tonali D, Vignati E. Magnetic Testing of coated components with high Dry Film Thickness (> 50 µm) using AC and DC Electromagnetic Yokes. e-Journal of Nondestructive Testing. 2026;31(7). doi:10.58286/33269

BibTeX
@article{Forno2026,
  author = {Forno, Erik Del and Marasco, Nicola and Verdino, Stefano and D'Amico, Riccardo and Tonali, Dario and Vignati, Enrico},
  title = {Magnetic Testing of coated components with high Dry Film Thickness (> 50 µm) using AC and DC Electromagnetic Yokes},
  journal = {e-Journal of Nondestructive Testing},
  year = {2026},
  volume = {31},
  number = {7},
  doi = {10.58286/33269}
}