Imaging and Sizing of Real SCC Using FMC/TFM and PCI
e-Journal of Nondestructive Testing · 2026-07 · 31 (7)
DOI: 10.58286/32933 ↗Kurz gefasst
Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-07. Verfasst von So Kitazawa und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Japan's basic energy plan envisions nuclear power supplying about 20% of electricity by FY2040, requiring shorter periodic inspections while maintaining safety. Ultrasonic testing of piping welds is a key task; however, detailed defect evaluation consumes a significant amount of person-hours. Promising techniques include Full Matrix Capture/Total Focusing Method (FMC/TFM) and Phase Coherence Imaging (PCI), though few studies address real, branched SCCs. In this study, SCCs were induced into a stainless steel specimen and inspected using FMC/TFM and PCI. The SNR was 19 for TFM and 120 for PCI, showing a six-fold improvement. By combining TFM and PCI and leveraging their strengths, defect evaluation is expected to become more accurate and efficient.
Zitieren
APA
Kitazawa, S., Ouchi, H., & Yoshida, I. (2026). Imaging and Sizing of Real SCC Using FMC/TFM and PCI. e-Journal of Nondestructive Testing, 31(7). https://doi.org/10.58286/32933
Vancouver
Kitazawa S, Ouchi H, Yoshida I. Imaging and Sizing of Real SCC Using FMC/TFM and PCI. e-Journal of Nondestructive Testing. 2026;31(7). doi:10.58286/32933
BibTeX
@article{Kitazawa2026,
author = {Kitazawa, So and Ouchi, Hirofumi and Yoshida, Isao},
title = {Imaging and Sizing of Real SCC Using FMC/TFM and PCI},
journal = {e-Journal of Nondestructive Testing},
year = {2026},
volume = {31},
number = {7},
doi = {10.58286/32933}
}