Impact of gaze deviation on the optic nerve sheath diameter metric: A prospective interventional study

Giada Cucciolini, Gaia Mignani iD, Giulio Costanzo, Francesco De Masi iD, Francesco Forfori iD, Francesco Corradi iD

The Ultrasound Journal · 09.06.2026 · 18 (1) · 18767

DOI: 10.5826/tuj.2026.18767 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Ultrasound Journal, online erschienen am 09.06.2026. Verfasst von Giada Cucciolini und 5 weiteren Autor:innen. Beteiligte Einrichtung: University of Pisa. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Optic nerve sheath diameter (ONSD) is a widely used non-invasive surrogate marker of intracranial pressure. Current recommendations state that measurements should be obtained with a neutral gaze. However, the effect of gaze deviation on ONSD has never been investigated. We aimed to evaluate the reliability of ONSD in case of gaze deviation and quantify the associated measurement error. A secondary aim was to assess whether bed inclination has a significant effect on ONSD values.

Methods

We conducted a prospective interventional study on 44 healthy volunteers during routine ocular ultrasound training. ONSD was measured bilaterally along the horizontal and vertical axes at 45° head-of-bed elevation in neutral and deviated gaze. After repositioning the bed to 0° and a 2-minute stabilization period, horizontal measurements were repeated. Measurements were performed according to current consensus recommendations and ALARA principles. Nonparametric analyses were used to analyse the results.

Results

Gaze deviation significantly reduced ONSD values across all axes and both eyes, with a consistent median difference of 0.8–1.0 mm (all p < 0.001) and large effect sizes. In contrast, no significant differences were observed between measurements obtained at 45° and 0° (p > 0.5).

Conclusions

Gaze deviation induces a predictable “stretching” effect on the optic nerve sheath, resulting in clinically relevant ONSD reduction. If confirmed in neurocritical populations, this systematic difference may allow estimation of neutral-gaze ONSD in non compliant patients and could form the basis for a dynamic test that estimates optic nerve sheath compliance.

Autor:innen und Institutionen

  • University of Pisa.
  • Department of Clinical and Experimental Medicine, Neurology Unit, University of Pisa, Pisa, Italy.
  • Department of Surgical, Medical, Molecular Pathology and Critical Care Medicine, University of Pisa, Via Savi 10, 56126, Pisa, Italy.
  • Departmental Structure of Neuroanesthesia and Intensive Care, Via Paradisa 2, 56124, Pisa, Italy.
  • University of Pisa, ATS Liguria-ASL5 Spezzino, Ospedale Civile Sant'Andrea, La Spezia.

ORCID-Profile: Gaia Mignani, Francesco De Masi, Francesco Forfori, Francesco Corradi

Zitieren

APA

Cucciolini, G., Mignani, G., Costanzo, G., De Masi, F., Forfori, F., & Corradi, F. (2026). Impact of gaze deviation on the optic nerve sheath diameter metric: A prospective interventional study. The Ultrasound Journal, 18(1), 18767. https://doi.org/10.5826/tuj.2026.18767

Vancouver

Cucciolini G, Mignani G, Costanzo G, De Masi F, Forfori F, Corradi F. Impact of gaze deviation on the optic nerve sheath diameter metric: A prospective interventional study. The Ultrasound Journal. 2026;18(1):18767. doi:10.5826/tuj.2026.18767

BibTeX
@article{Cucciolini2026,
  author = {Cucciolini, Giada and Mignani, Gaia and Costanzo, Giulio and De Masi, Francesco and Forfori, Francesco and Corradi, Francesco},
  title = {Impact of gaze deviation on the optic nerve sheath diameter metric: A prospective interventional study},
  journal = {The Ultrasound Journal},
  year = {2026},
  volume = {18},
  number = {1},
  pages = {18767},
  doi = {10.5826/tuj.2026.18767}
}
Kostenlos starten →