EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

3D Imaging and Measurement of Optic Nerve Sheath Diameter

Ronald H Silverman, Cédric Venuat, Lionel Letoffet, Jeffrey A Ketterling

Translational Vision Science & Technology · 09.07.2026 · 15 (7) · 11

DOI: 10.1167/tvst.15.7.11 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 09.07.2026. Verfasst von Ronald H Silverman und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Columbia University Irving Medical Center, New York, NY, USA. Hauptthemen laut MEDLINE: Optic Nerve, Imaging, Three-Dimensional, Intracranial Hypertension. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NEI NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The subarachnoid space between the dura and the pia mater is filled with cerebrospinal fluid, and, with elevated intracranial pressure, optic nerve sheath diameter (ONSD) will consequently increase. ONSD measurement thus serves as a non-invasive means for detecting intracranial hypertension. B-scans, however, only measure ONSD in a plane, and axial symmetry is assumed. In this study, we evaluated a novel ultrasound system for three-dimensional (3D) imaging and measurement of ONSD.

Methods

We imaged both eyes of 18 subjects using 15-MHz B-scans and a prototype 3D system. In this system, a focused single-element transducer was moved in a spiral pattern to sweep out a volume in approximately 5 seconds. We compared transverse B-scan ONSD measurements with values derived from cross-sections of 3D scans.

Results

Mean ONSD was 5.32 ± 0.79 mm by B-scan and 5.57 ± 0.61 mm by 3D. The larger measurement by 3D was borderline statistically significant (P = 0.05). The within-eye variability between repeated measurements was comparable. Bland-Altman analysis showed no trend associated with increasing or decreasing ONSD. Eccentricity of 3D ONSD best-fit ellipses to nerve coronal sections averaged 0.51 ± 0.098.

Conclusions

The 3D prototype 5-second acquisition was faster than prior mechanical systems based on single element probes but still somewhat vulnerable to motion artifacts. The ability to assess the ONSD in three dimensions rather than as a transverse cross-section offers an avenue toward improved assessment of nerve anatomy and detection of intracranial hypertension. Translational Relevance: 3D imaging of the optic nerve offers improved assessment of changes associated with elevated intracranial pressure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Optic NerveImaging, Three-DimensionalIntracranial HypertensionHumansUltrasonographyFemaleMaleAdultMiddle AgedReproducibility of Results

Autor:innen und Institutionen

  • Department of Ophthalmology, Columbia University Irving Medical Center, New York, NY, USA.
  • Quantel Medical, Cournon d'Auvergne, France.
  • Department of Radiology, Weill Cornell Medicine, New York, NY, USA.

Förderung

  • NEI NIH HHS
  • NIBIB NIH HHS

Zitieren

APA

Silverman, R. H., Venuat, C., Letoffet, L., & Ketterling, J. A. (2026). 3D Imaging and Measurement of Optic Nerve Sheath Diameter. Translational Vision Science & Technology, 15(7), 11. https://doi.org/10.1167/tvst.15.7.11

Vancouver

Silverman RH, Venuat C, Letoffet L, Ketterling JA. 3D Imaging and Measurement of Optic Nerve Sheath Diameter. Translational Vision Science & Technology. 2026;15(7):11. doi:10.1167/tvst.15.7.11

BibTeX
@article{Silverman2026,
  author = {Silverman, Ronald H and Venuat, Cédric and Letoffet, Lionel and Ketterling, Jeffrey A},
  title = {3D Imaging and Measurement of Optic Nerve Sheath Diameter},
  journal = {Translational Vision Science & Technology},
  year = {2026},
  volume = {15},
  number = {7},
  pages = {11},
  doi = {10.1167/tvst.15.7.11}
}
Kostenlos starten →