EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Assessment of the Mechanical Properties of Three Commercially Available Thermoplastic Aligner Materials Used for Orthodontic Treatment

Alok Ranjan, Anil Kumar Biradar, Ankita Patel, Vanessa Varghese, Ankita Pawar, Rohit Kulshrestha

Iranian Journal of Orthodontics · 31.07.2021 · 15 (2)

DOI: 10.5812/ijo.116573 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Iranian Journal of Orthodontics, online erschienen am 31.07.2021. Verfasst von Alok Ranjan und 5 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This studied aimed to measure the yield strength and stress relaxation properties of three commercially available thermoplastic aligner materials.

Methods

The three different thermoplastics aligner materials Duran (Scheu, Iserlohn, Germany), Erkodur (Pfalzgrafenweiler, Erkodent, Germany) and Track (Forestadent, Germany) were selected. A three-point bending test was carried out via the universal testing machine to measure their yield strength and stress relaxation properties. An independent t-test was performed for intergroup comparison. P-value < 0.05 was set as the level of significance.

Results

All the selected three polymers liberate a notable amount of stress during 24 hours. The highest stress release was observed in Duran i.e. 18.96 N/cm2 as compared to Erkodur, which was 13.96 N/cm2 and Track, which was 13.18 N/cm2. The yield strength of Duran was the highest (75.85 Mpa) compared to Track and Erkodur with the yield strength of 52.75 Mpa and 55.86 Mpa, respectively.

Conclusions

Tooth movement is influenced by the composition of aligner material and its thickness. Duran had the highest stress release and yield strength. Stress released by different aligners exceeds around half of the initial stress value, which directly affects the orthodontic force application and subsequent tooth movement.

Zitieren

APA

Ranjan, A., Biradar, A. K., Patel, A., Varghese, V., Pawar, A., & Kulshrestha, R. (2021). Assessment of the Mechanical Properties of Three Commercially Available Thermoplastic Aligner Materials Used for Orthodontic Treatment. Iranian Journal of Orthodontics, 15(2). https://doi.org/10.5812/ijo.116573

Vancouver

Ranjan A, Biradar AK, Patel A, Varghese V, Pawar A, Kulshrestha R. Assessment of the Mechanical Properties of Three Commercially Available Thermoplastic Aligner Materials Used for Orthodontic Treatment. Iranian Journal of Orthodontics. 2021;15(2). doi:10.5812/ijo.116573

BibTeX
@article{Ranjan2021,
  author = {Ranjan, Alok and Biradar, Anil Kumar and Patel, Ankita and Varghese, Vanessa and Pawar, Ankita and Kulshrestha, Rohit},
  title = {Assessment of the Mechanical Properties of Three Commercially Available Thermoplastic Aligner Materials Used for Orthodontic Treatment},
  journal = {Iranian Journal of Orthodontics},
  year = {2021},
  volume = {15},
  number = {2},
  doi = {10.5812/ijo.116573}
}
Kostenlos starten →