EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Analysis of orthodontic aligner biocompatibility: leachable compounds of different aligner materials

Thomas Wendl, Erich Leitner, Brigitte Wendl, Peter Proff

Biomedical Engineering / Biomedizinische Technik · 24.02.2026 · 71 (1) · 31-38

DOI: 10.1515/bmt-2025-0131 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Engineering / Biomedizinische Technik, online erschienen am 15.09.2025. Verfasst von Thomas Wendl und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, University of Regensburg, Regensburg, Germany. Hauptthemen laut MEDLINE: Biocompatible Materials, Phenols. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives the aim of this study was to clarify the biocompatibility of different tooth repositioning splints (aligners). This included the characterization of the volatile fraction by headspace solid phase microextraction coupled to gas chromatography mass spectrometry, simulation of leachable organic compounds using artificial saliva and the quantitation of bisphenol A and bisphenol S after extraction. Methods Four different aligners were characterized in this study, these included two splints with novel shape memory properties: a printable aligner made of the resin Tera Harz TC-85 DAC (Graphy Inc., South Korea) and a self-manufactured SMP-Aligner consisting of the components polypropylene carbonate and thermoplastic polyurethane. The other two aligners were conventional, thermoformable aligners: CA® Pro Clear Aligner (Scheu Dental GmbH, Germany) and Erkodur-al (Erkodent Erich Kopp GmbH, Germany). Results no BPA was found in all four samples after 72 h. BPS was found in one Aligner. The most leachable compounds were found in the samples of the SMP- and the direct printed Graphy-Aligner. Most of the compound release occurred during the first 24 h. Conclusions the cumulative exposure effect from aligner wear should be carefully considered, although the current research indicates that the levels of leachable compounds are generally low.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biocompatible MaterialsPhenolsBenzhydryl CompoundsMaterials TestingHumansGas Chromatography-Mass SpectrometryBisphenol A Compounds

Stichwörter der Autor:innen

alignerbiocompatibilitybisphenolsdirect printorthodonticsthermoformed

Substanzen

Biocompatible MaterialsBenzhydryl Compoundsbisphenol APhenolsBisphenol A Compounds

Autor:innen und Institutionen

  • Department of Orthodontics, University of Regensburg, Regensburg, Germany.
  • Institute of Analytical Chemistry and Food Chemistry, Graz University of Technology, Graz, Austria.
  • Department of Oral Surgery and Orthodontics, Medical University Graz, Graz, Austria.

Zitieren

APA

Wendl, T., Leitner, E., Wendl, B., & Proff, P. (2026). Analysis of orthodontic aligner biocompatibility: leachable compounds of different aligner materials. Biomedical Engineering / Biomedizinische Technik, 71(1), 31-38. https://doi.org/10.1515/bmt-2025-0131

Vancouver

Wendl T, Leitner E, Wendl B, Proff P. Analysis of orthodontic aligner biocompatibility: leachable compounds of different aligner materials. Biomedical Engineering / Biomedizinische Technik. 2026;71(1):31-38. doi:10.1515/bmt-2025-0131

BibTeX
@article{Wendl2026,
  author = {Wendl, Thomas and Leitner, Erich and Wendl, Brigitte and Proff, Peter},
  title = {Analysis of orthodontic aligner biocompatibility: leachable compounds of different aligner materials},
  journal = {Biomedical Engineering / Biomedizinische Technik},
  year = {2026},
  volume = {71},
  number = {1},
  pages = {31--38},
  doi = {10.1515/bmt-2025-0131}
}