EUVIMEDEUVIMED entdecken
Open Access

Feasibility and Utility of Infrared Thermography for Intraoperative Temperature Monitoring in Cold Agglutinin Disease during Cardiopulmonary Bypass

Yoshiyuki Nishimura, Go Kuwahara, Hideichi Wada

Annals of Thoracic and Cardiovascular Surgery · 2026 · 32 (1) · n/a

DOI: 10.5761/atcs.oa.26-00158 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Thoracic and Cardiovascular Surgery, 2026. Verfasst von Yoshiyuki Nishimura und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Mie Heart Center, Mie, Japan. Hauptthemen laut MEDLINE: Thermography, Anemia, Hemolytic, Autoimmune, Cardiopulmonary Bypass, Monitoring, Intraoperative. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Cold agglutinin disease (CAD) is a rare autoimmune hemolytic disorder that poses significant challenges during cardiovascular surgery requiring cardiopulmonary bypass (CPB), owing to the risk of cold-induced red blood cell agglutination. METHODS: This study evaluated the utility of a noninvasive and easy-to-use infrared thermography device for intraoperative temperature assessment to address the risk of hypothermia-associated complications in CAD. Among 416 open-heart surgeries performed at our institution between September 2013 and December 2023, 5 cases (1.2%) involved CAD. RESULTS: Temperature control was tailored to each patient's thermal amplitude (19°C-26°C). CPB was conducted at systemic temperatures of 34°C-36°C, and cardioplegia was administered at 28°C-32°C, both above the agglutinin threshold. All 5 patients successfully underwent surgery and were discharged. Temperature management was particularly critical during sternotomy, CPB initiation, and cardioplegia delivery. In 4 cases, infrared thermography was used for monitoring of epicardial and cardioplegic temperatures, which was associated with an uneventful postoperative course. In contrast, 1 case without thermographic monitoring developed postoperative myocardial infarction and decreased cardiac function. CONCLUSION: These findings suggest that noninvasive thermography may serve as a useful adjunct for real-time temperature surveillance during cardiac surgery in patients with CAD, providing information that is not captured by systemic temperature monitoring alone.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ThermographyAnemia, Hemolytic, AutoimmuneCardiopulmonary BypassMonitoring, IntraoperativeInfrared RaysCardiac Surgical ProceduresBody TemperatureHypothermiaHumansFemalePredictive Value of TestsMaleMiddle AgedTreatment OutcomeAgedFeasibility StudiesHeart Arrest, InducedRisk Factors

Stichwörter der Autor:innen

cardiac surgerycardiopulmonary bypasscold agglutinin diseaseinfrared thermography

Autor:innen und Institutionen

  • Department of Cardiovascular Surgery, Mie Heart Center, Mie, Japan.
  • Department of Cardiovascular Surgery, Fukuoka University, Fukuoka, Fukuoka, Japan.

Zitieren

APA

Nishimura, Y., Kuwahara, G., & Wada, H. (2026). Feasibility and Utility of Infrared Thermography for Intraoperative Temperature Monitoring in Cold Agglutinin Disease during Cardiopulmonary Bypass. Annals of Thoracic and Cardiovascular Surgery, 32(1), n/a. https://doi.org/10.5761/atcs.oa.26-00158

Vancouver

Nishimura Y, Kuwahara G, Wada H. Feasibility and Utility of Infrared Thermography for Intraoperative Temperature Monitoring in Cold Agglutinin Disease during Cardiopulmonary Bypass. Annals of Thoracic and Cardiovascular Surgery. 2026;32(1):n/a. doi:10.5761/atcs.oa.26-00158

BibTeX
@article{Nishimura2026,
  author = {Nishimura, Yoshiyuki and Kuwahara, Go and Wada, Hideichi},
  title = {Feasibility and Utility of Infrared Thermography for Intraoperative Temperature Monitoring in Cold Agglutinin Disease during Cardiopulmonary Bypass},
  journal = {Annals of Thoracic and Cardiovascular Surgery},
  year = {2026},
  volume = {32},
  number = {1},
  pages = {n/a},
  doi = {10.5761/atcs.oa.26-00158}
}
Kostenlos starten →