EUVIMEDEUVIMED entdecken
Open Access

Usefulness of Artificial Pneumothorax during Totally Endoscopic Off-Pump Left Atrial Appendage Closure and Surgical Ablation

Shunsuke Sato, Takashi Azami, Jun Fujisue, Kyozo Inoue, Kenji Okada

Annals of Thoracic and Cardiovascular Surgery · 2025

DOI: 10.5761/atcs.oa.24-00156 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Thoracic and Cardiovascular Surgery, 2025. Verfasst von Shunsuke Sato und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Yodogawa Christian Hospital, Osaka, Osaka, Japan. Hauptthemen laut MEDLINE: Atrial Appendage, Atrial Fibrillation, Pneumothorax, Artificial, Catheter Ablation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 7 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: In totally endoscopic off-pump left atrial appendage (LAA) closure and surgical ablation, securing the operative field is sometimes difficult in some patients because of a narrow working space caused by an elevated diaphragm or ventricles. In this study, we aimed to investigate the effectiveness of a method that facilitates securing the operative field using an artificial pneumothorax. METHODS: We analyzed 71 consecutive patients who underwent totally endoscopic off-pump LAA closure and bilateral pulmonary vein isolation. The factors contributing to the reduction in operative time were examined. The patients were divided into the following 2 groups according to whether or not an artificial pneumothorax was used: Group C comprised 24 patients without an artificial pneumothorax and Group A comprised 47 patients with an artificial pneumothorax. RESULTS: There were no hospital deaths or major complications. The operative time was significantly shorter in Group A (108 ± 26 minutes) than in Group C (198 ± 77 minutes) (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial AppendageAtrial FibrillationPneumothorax, ArtificialCatheter AblationEndoscopyPulmonary VeinsHumansFemaleMaleTreatment OutcomeOperative TimeAgedMiddle AgedTime FactorsRetrospective StudiesLeft Atrial Appendage Closure

Stichwörter der Autor:innen

artificial pneumothoraxatrial fibrillationleft atrial appendage closuremazeminimally invasive cardiac surgery

Autor:innen und Institutionen

  • Department of Cardiovascular Surgery, Yodogawa Christian Hospital, Osaka, Osaka, Japan.
  • Department of Cardiovascular Surgery, Kobe University, Kobe, Hyogo, Japan.

Zitieren

APA

Sato, S., Azami, T., Fujisue, J., Inoue, K., & Okada, K. (2025). Usefulness of Artificial Pneumothorax during Totally Endoscopic Off-Pump Left Atrial Appendage Closure and Surgical Ablation. Annals of Thoracic and Cardiovascular Surgery. https://doi.org/10.5761/atcs.oa.24-00156

Vancouver

Sato S, Azami T, Fujisue J, Inoue K, Okada K. Usefulness of Artificial Pneumothorax during Totally Endoscopic Off-Pump Left Atrial Appendage Closure and Surgical Ablation. Annals of Thoracic and Cardiovascular Surgery. 2025. doi:10.5761/atcs.oa.24-00156

BibTeX
@article{Sato2025,
  author = {Sato, Shunsuke and Azami, Takashi and Fujisue, Jun and Inoue, Kyozo and Okada, Kenji},
  title = {Usefulness of Artificial Pneumothorax during Totally Endoscopic Off-Pump Left Atrial Appendage Closure and Surgical Ablation},
  journal = {Annals of Thoracic and Cardiovascular Surgery},
  year = {2025},
  doi = {10.5761/atcs.oa.24-00156}
}
Kostenlos starten →