Experimental determination of indoor air concentration of 5-chloro-2-methylisothiazol-3(2H)-one/ 2-methylisothiazol-3(2H)-one (CMIT/MIT) emitted by the use of humidifier disinfectant

Seon-Kyung Park, Hwi-Soo Seol, Hee-Jin Park, Yoon-Seob Kim, Seung-Hun Ryu, Jaehoon Kim, Suejin Kim, Jong-Hyeon Lee, Jung-Hwan Kwon

Environmental Analysis Health and Toxicology · 2020-06-30 · 35 (2) · e2020008

DOI: 10.5620/eaht.e2020008 ↗

At a glance

Journal article in Environmental Analysis Health and Toxicology, published online on 2020-06-30. Written by Seon-Kyung Park and 8 co-authors. Institution: Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, Korea. Cited 23 times so far (Crossref); 31 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: National Institute of Environmental Research, Ministry of Environment.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

A mixture of 5-chloro-2-methylisothiazol-3(2H)-one/2-methylisothiazol-3(2H)-one (CMIT/MIT) had been used as an active ingredient in humidifier disinfectants (HDs). Owing to its high reactivity, the atmospheric concentration of CMIT/MIT, following its use in HD, would be lower than expected assuming that it is removed by ventilation only. In order to evaluate the exposure concentration of CMIT/MIT used as an HD, room-scale chamber studies were conducted under plausible use of three different HD doses at air change rates (ACR) of 0.3, 0.5, and 1.0 h-1. Atmospheric CMIT/MIT was sampled using two serial impingers containing deionized water after the attainment of steady state. Water samples in which CMIT/MIT was dissolved were concentrated using a cosolvent evaporation method with efficiencies of 35.5 and 77.9% for CMIT and MIT, respectively. The estimated air concentration, assuming that all the CMIT/MIT is absorbed in deionized water, increased linearly with increasing emission rate, but was independent of the ACR. This indicates that the removal rate of CMIT/MIT via chemical reactions is more than the removal rate by ventilation. Further investigations on homogeneous and heterogeneous chemical reactions of CMIT/MIT under ambient conditions are necessary to understand the actual exposure concentration of the mixture in HD.

Subjects

Author keywords

biocideschemical reactionschloromethyl/methyl-isothiazolinone (CMIT/MIT)health risk assessmentindoor air

Authors and institutions

  • Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, Korea.
  • EH R&C, Environmental Research Center, 410 Jeongseojin-ro, Seo-gu, Incheon, Korea.
  • Humidifier Disinfectant Health Center, National Institute of Environmental Research, 42 Hwangyong-ro, Seo-gu, Incheon, Korea.

Funding

  • National Institute of Environmental Research
  • Ministry of Environment

Cite

APA

Park, S. K., Seol, H. S., Park, H. J., Kim, Y. S., Ryu, S. H., Kim, J., Kim, S., Lee, J. H., & Kwon, J. H. (2020). Experimental determination of indoor air concentration of 5-chloro-2-methylisothiazol-3(2H)-one/ 2-methylisothiazol-3(2H)-one (CMIT/MIT) emitted by the use of humidifier disinfectant. Environmental Analysis Health and Toxicology, 35(2), e2020008. https://doi.org/10.5620/eaht.e2020008

Vancouver

Park SK, Seol HS, Park HJ, Kim YS, Ryu SH, Kim J, et al. Experimental determination of indoor air concentration of 5-chloro-2-methylisothiazol-3(2H)-one/ 2-methylisothiazol-3(2H)-one (CMIT/MIT) emitted by the use of humidifier disinfectant. Environmental Analysis Health and Toxicology. 2020;35(2):e2020008. doi:10.5620/eaht.e2020008

BibTeX
@article{Park2020,
  author = {Park, Seon-Kyung and Seol, Hwi-Soo and Park, Hee-Jin and Kim, Yoon-Seob and Ryu, Seung-Hun and Kim, Jaehoon and Kim, Suejin and Lee, Jong-Hyeon and Kwon, Jung-Hwan},
  title = {Experimental determination of indoor air concentration of 5-chloro-2-methylisothiazol-3(2H)-one/ 2-methylisothiazol-3(2H)-one (CMIT/MIT) emitted by the use of humidifier disinfectant},
  journal = {Environmental Analysis Health and Toxicology},
  year = {2020},
  volume = {35},
  number = {2},
  pages = {e2020008},
  doi = {10.5620/eaht.e2020008}
}
Start for free →