EUVIMEDEUVIMED entdecken
Crossref

PERFORMANCE EVALUATION OF STACK VENTILATION SYSTEMS IN RESIDENTIAL BUILDINGS: EXPERIMENTAL COMPARISON OF PASSIVE CHIMNEYENHANCEMENTS

Romana Antczak - Jarząbska

Zeszyty Naukowe SGSP · 31.03.2026 · 1 (97) · 61-76

DOI: 10.5604/01.3001.0055.7092 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Zeszyty Naukowe SGSP, erschienen am 31.03.2026. Verfasst von Romana Antczak - Jarząbska. Die Arbeit nennt 14 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article investigates methods for enhancing the efficiency of gravity-driven ventilation in residential buildings, with particular emphasis on chimney-based passive solutions. Full-scale in situ experiments were conducted in a single-family house located in a temperate climate in northern Poland during a four-month transitional period (August–November). Three chimney configurations were analysed: a traditional ceramic brick chimney (TYPE I), a solar chimney with a transparent glazed enclosure above the roofline (TYPE II), and a traditional chimney equipped with a rotary-type chimney cap (TYPE III).Ventilation performance was evaluated using the air change rate (ACH) under varying wind and solar radiation conditions. The results show that, compared to the reference configuration (TYPE I – traditional chimney), the solar chimney (TYPE II) increased the average ACH by approximately 14%, particularly under low-wind conditions (0–2 m/s) and solar radiation above 100 W/m. The greatest improvement was achieved by the rotary-type chimney cap (TYPE III), which increased the average ACH by about 35%, with maximum values reaching 0.40 h⁻ under wind speeds of 2–5 m/s. These findings demonstrate that passive architectural modifications can significantly enhance gravity-driven ventilation and thereby improve indoor air quality in residential buildings.In addition to ventilation performance, the impact of the rotary chimney cap on heating energy demand was assessed over a 24-month monitoring period. The installation of the chimney cap reduced annual heating energy consumption from 33.74 GJ to 27.21 GJ, corresponding to an energy saving of 6.53 GJ (approximately 19%). The results demonstrate that passive chimney modifications not only enhance gravity ventilation efficiency but also contribute to measurable reductions in heating energy demand, supporting their application in energy-efficient residential buildings.

Zitieren

APA

Jarząbska, R. A. (2026). PERFORMANCE EVALUATION OF STACK VENTILATION SYSTEMS IN RESIDENTIAL BUILDINGS: EXPERIMENTAL COMPARISON OF PASSIVE CHIMNEYENHANCEMENTS. Zeszyty Naukowe SGSP, 1(97), 61-76. https://doi.org/10.5604/01.3001.0055.7092

Vancouver

Jarząbska RA. PERFORMANCE EVALUATION OF STACK VENTILATION SYSTEMS IN RESIDENTIAL BUILDINGS: EXPERIMENTAL COMPARISON OF PASSIVE CHIMNEYENHANCEMENTS. Zeszyty Naukowe SGSP. 2026;1(97):61-76. doi:10.5604/01.3001.0055.7092

BibTeX
@article{Jarzbska2026,
  author = {Jarząbska, Romana Antczak -},
  title = {PERFORMANCE EVALUATION OF STACK VENTILATION SYSTEMS IN RESIDENTIAL BUILDINGS: EXPERIMENTAL COMPARISON OF PASSIVE CHIMNEYENHANCEMENTS},
  journal = {Zeszyty Naukowe SGSP},
  year = {2026},
  volume = {1},
  number = {97},
  pages = {61--76},
  doi = {10.5604/01.3001.0055.7092}
}
Kostenlos starten →