EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Passive Ventilation of Residential Buildings Using the Trombe Wall

Khrystyna Myroniuk, Yurii Furdas, Vasyl Zhelykh, Mariusz Adamski, Olena Gumen, Valerii Savin, Stergios-Aristoteles Mitoulis

Buildings · 03.10.2024 · 14 (10) · 3154

DOI: 10.3390/buildings14103154 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 03.10.2024. Verfasst von Khrystyna Myroniuk und 6 weiteren Autor:innen. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The article explores passive systems for regulating microclimates in residential settings, with a focus on modular constructions. It investigates the use of the trombe wall system for passive ventilation to ensure comfort and hygiene. The study examines building designs that enable effective air circulation without using mechanical systems. Furthermore, the effectiveness of the passive system of using solar energy with the trombe wall as a ventilation device in modular houses has been experimentally confirmed. Although the research confirms the effectiveness of this solar system in modular homes, there is limited documentation regarding its overall efficiency, particularly concerning the impact of the surface pressure coefficient on ventilation. The study establishes the correlations governing the thermosiphon collector’s effectiveness at varying air layer thicknesses. Optimal parameters, such as maximum air consumption (L = 120 m3h−1), are identified at an air layer thickness (δ) of 100 mm and outlet openings area (F) of 0.056 m2. These findings pave the way for improving passive systems aimed at maintaining optimal thermal and air conditions in modern homes. The findings suggest the potential for more efficient and sustainable housing solutions. Further research is essential to understand how factors like building design and wind speed affect ventilation system efficacy.

Zitieren

APA

Myroniuk, K., Furdas, Y., Zhelykh, V., Adamski, M., Gumen, O., Savin, V., & Mitoulis, S. (2024). Passive Ventilation of Residential Buildings Using the Trombe Wall. Buildings, 14(10), 3154. https://doi.org/10.3390/buildings14103154

Vancouver

Myroniuk K, Furdas Y, Zhelykh V, Adamski M, Gumen O, Savin V, et al. Passive Ventilation of Residential Buildings Using the Trombe Wall. Buildings. 2024;14(10):3154. doi:10.3390/buildings14103154

BibTeX
@article{Myroniuk2024,
  author = {Myroniuk, Khrystyna and Furdas, Yurii and Zhelykh, Vasyl and Adamski, Mariusz and Gumen, Olena and Savin, Valerii and Mitoulis, Stergios-Aristoteles},
  title = {Passive Ventilation of Residential Buildings Using the Trombe Wall},
  journal = {Buildings},
  year = {2024},
  volume = {14},
  number = {10},
  pages = {3154},
  doi = {10.3390/buildings14103154}
}
Kostenlos starten →