EUVIMEDEUVIMED entdecken
Crossref

Radiochromic film calibrationwith photon, electron and protonbeams – Interchangeability study

Adam Spyra, Izabela Skwira-Chalot, Marta Bałamut, Klaudia Benisz, Joanna Matulewicz, Tomasz Matulewicz, Michał Półtorak, Marzena Rydygier, Przemysław Sękowski, Agata Taranienko, Katarzyna Ziemba

Bio-Algorithms and Med-Systems · 18.12.2025 · 21 (1) · 71-78

DOI: 10.5604/01.3001.0055.4654 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bio-Algorithms and Med-Systems, erschienen am 18.12.2025. Verfasst von Adam Spyra und 10 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective:This study aimed to evaluate the feasibility of calibrating radiochromic films using different types of radiation. By comparing photon, electron and proton beams, we assessed whether calibration can be performed without relying on clinically restricted medical beams.

Methods

Radiochromic films were irradiated with photon, electron and proton beams, each delivering a fixed dose in the 1–14 Gy range. The response of three colour channels – red, green and blue – was analysed. Calibration curves were established for each channel, and their sensitivity and consistency across different beam types were compared.

Results

Among the three channels, the green fraction showed the highest sensitivity to ionising radiation. Its intensity calibration was consistent across all investigated beam types, indicating that the response of the green channel is independent of the radiation quality.

Conclusions

Radiochromic film calibration can be reliably performed using photon, electron or proton beams. Since the green channel provides stable and reproducible results, any of these radiation sources can be used for calibration. This finding removes the need for exclusive access to clinical medical beams, simplifying the calibration process and improving accessibility for research and quality assurance applications.

Zitieren

APA

Spyra, A., Skwira-Chalot, I., Bałamut, M., Benisz, K., Matulewicz, J., Matulewicz, T., Półtorak, M., Rydygier, M., Sękowski, P., Taranienko, A., & Ziemba, K. (2025). Radiochromic film calibrationwith photon, electron and protonbeams – Interchangeability study. Bio-Algorithms and Med-Systems, 21(1), 71-78. https://doi.org/10.5604/01.3001.0055.4654

Vancouver

Spyra A, Skwira-Chalot I, Bałamut M, Benisz K, Matulewicz J, Matulewicz T, et al. Radiochromic film calibrationwith photon, electron and protonbeams – Interchangeability study. Bio-Algorithms and Med-Systems. 2025;21(1):71-78. doi:10.5604/01.3001.0055.4654

BibTeX
@article{Spyra2025,
  author = {Spyra, Adam and Skwira-Chalot, Izabela and Bałamut, Marta and Benisz, Klaudia and Matulewicz, Joanna and Matulewicz, Tomasz and Półtorak, Michał and Rydygier, Marzena and Sękowski, Przemysław and Taranienko, Agata and Ziemba, Katarzyna},
  title = {Radiochromic film calibrationwith photon, electron and protonbeams – Interchangeability study},
  journal = {Bio-Algorithms and Med-Systems},
  year = {2025},
  volume = {21},
  number = {1},
  pages = {71--78},
  doi = {10.5604/01.3001.0055.4654}
}
Kostenlos starten →