Optically stimulated luminescence system as an alternative for radiochromic film for 2D reference dosimetry in UHDR electron beams
Physica Medica · 2023-10 · 114 · 103147
DOI: 10.1016/j.ejmp.2023.103147 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Medica, 2023-10. Verfasst von Verdi Vanreusel und 13 weiteren Autor:innen. Beteiligte Einrichtung: Research in Dosimetric Applications, SCK CEN, Boeretang 200, 2400 Mol, Belgium; CORE, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belg…. Hauptthemen laut MEDLINE: Electrons, Optically Stimulated Luminescence Dosimetry. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Agentschap Innoveren en Ondernemen, European Metrology Programme for Innovation and Research.
Abstract (Originalsprache)
Radiotherapy is part of the treatment of over 50% of cancer patients. Its efficacy is limited by the radiotoxicity to the healthy tissue. FLASH-RT is based on the biological effect that ultra-high dose rates (UHDR) and very short treatment times strongly reduce normal tissue toxicity, while preserving the anti-tumoral effect. Despite many positive preclinical results, the translation of FLASH-RT to the clinic is hampered by the lack of accurate dosimetry for UHDR beams. To date radiochromic film is commonly used for dose assessment but has the drawback of lengthy and cumbersome read out procedures. In this work, we investigate the equivalence of a 2D OSL system to radiochromic film dosimetry in terms of dose rate independency. The comparison of both systems was done using the ElectronFlash linac. We investigated the dose rate dependence by variation of the (1) modality, (2) pulse repetition frequency, (3) pulse length and (4) source to surface distance. Additionally, we compared the 2D characteristics by field size measurements. The OSL calibration showed transferable between conventional and UHDR modality. Both systems are equally independent of average dose rate, pulse length and instantaneous dose rate. The OSL system showed equivalent in field size determination within 3 sigma. We show the promising nature of the 2D OSL system to serve as alternative for radiochromic film in UHDR electron beams. However, more in depth characterization is needed to assess its full potential.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research in Dosimetric Applications, SCK CEN, Boeretang 200, 2400 Mol, Belgium; CORE, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium; Iridium Netwerk, Oosterveldlaan 22, 2610 Wilrijk, Belgium. Electr…
- CORE, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium; Iridium Netwerk, Oosterveldlaan 22, 2610 Wilrijk, Belgium.
- Sordina IORT Technologies S.p.A., Via dell'Industria, 1/A, 04011 Aprilia, Latina, Italy.
- CORE, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium.
- NuTeC, CMK, Hasselt University, Wetenschapspark 27, 3590 Diepenbeek, Belgium.
- Agfa N.V., Septestraat 27, 2640 Mortsel, Belgium.
Förderung
- Agentschap Innoveren en Ondernemen
- European Metrology Programme for Innovation and Research
Zitieren
APA
Vanreusel, V., Gasparini, A., Galante, F., Mariani, G., Pacitti, M., Colijn, A., Reniers, B., Yalvac, B., Vandenbroucke, D., Peeters, M., Leblans, P., Felici, G., Verellen, D., & de Freitas Nascimento, L. (2023). Optically stimulated luminescence system as an alternative for radiochromic film for 2D reference dosimetry in UHDR electron beams. Physica Medica, 114, 103147. https://doi.org/10.1016/j.ejmp.2023.103147
Vancouver
Vanreusel V, Gasparini A, Galante F, Mariani G, Pacitti M, Colijn A, et al. Optically stimulated luminescence system as an alternative for radiochromic film for 2D reference dosimetry in UHDR electron beams. Physica Medica. 2023;114:103147. doi:10.1016/j.ejmp.2023.103147
BibTeX
@article{Vanreusel2023,
author = {Vanreusel, Verdi and Gasparini, Alessia and Galante, Federica and Mariani, Giulia and Pacitti, Matteo and Colijn, Arnaud and Reniers, Brigitte and Yalvac, Burak and Vandenbroucke, Dirk and Peeters, Marc and Leblans, Paul and Felici, Giuseppe and Verellen, Dirk and de Freitas Nascimento, Luana},
title = {Optically stimulated luminescence system as an alternative for radiochromic film for 2D reference dosimetry in UHDR electron beams},
journal = {Physica Medica},
year = {2023},
volume = {114},
pages = {103147},
doi = {10.1016/j.ejmp.2023.103147}
}
EUVIMED