EUVIMEDEUVIMED entdecken
Open Access

MV CBCT based assessment of setup uncertainties and planning target volume margin in head and neck cancer

Debanjan Sikdar, Ajay S Krishnan, R S Namitha, Abhishek Chakravarty, Dhiraj Gupta, Sweety Gupta, Arvind Kumar, Deepa Joseph, Manoj Gupta

Reports of Practical Oncology and Radiotherapy · 17.02.2024

DOI: 10.5603/rpor.99361 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Reports of Practical Oncology and Radiotherapy, online erschienen am 17.02.2024. Verfasst von Debanjan Sikdar und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology AIIMS Rishikesh, India. Die Arbeit wurde bisher 3-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Set-up errors are an undesirable part of the radiation treatment process. The goal of online imaging is to increase treatment accuracy by reducing the set-up errors. This study aimed to determine the daily variation of patient set-up uncertainties and planning target volume (PTV) margins for head and neck cancer patients using pre-treatment verification by mega voltage cone-beam computed tomography (MV-CBCT). Materials and methods: This retrospective study was internal record base of head and neck (H&N) cancer patients treated with definitive radiotherapy, adjuvant radiotherapy, and hypo-fractionated radiotherapy at our institution since the implementation of HalcyonTM 2.0 machine (Varian, US). Errors collected from each patient setup were recorded and evaluated for each direction [medio-lateral (ML), supero-inferior (SI), antero-posterior (AP)] discretely. For each patient, the systematic error (∑) and random error (σ) were collected. Clinical target volume (CTV) to planning target volume (PTV) margin was calculated using International Commission on Radiation Units and Measurements (ICRU) 62 (PTV margin = ), Stroom’s (PTV margin = 2∑ + 0.7σ), and Van Herk’s (PTV margin = 2.5∑ + 0.7σ) formula.

Results

A total of 7900 pre-treatment CBCT scans of 301 patients were analyzed and a total of 23,000 error measurements in the ML, SI, and AP directions were recorded. For all of our H&N cancer patients, the CTV to PTV margin, calculated from the van Herk formula for the head and neck patients was 0.49 mm in the anteroposterior axis.

Conclusions

An isometric PTV margin of 5 mm may be considered safe if daily imaging is not being done. In case daily online pretreatment imaging is being utilized, further reduction of PTV margin is possible.

Schlagwörter

Stichwörter der Autor:innen

imagingplanning target volumeradiotherapyset up errors

Autor:innen und Institutionen

  • Department of Radiation Oncology AIIMS Rishikesh, India.
  • Department of Radiation Oncology HBCH TMC, Varanasi, India.

Zitieren

APA

Sikdar, D., Krishnan, A. S., Namitha, R. S., Chakravarty, A., Gupta, D., Gupta, S., Kumar, A., Joseph, D., & Gupta, M. (2024). MV CBCT based assessment of setup uncertainties and planning target volume margin in head and neck cancer. Reports of Practical Oncology and Radiotherapy. https://doi.org/10.5603/rpor.99361

Vancouver

Sikdar D, Krishnan AS, Namitha RS, Chakravarty A, Gupta D, Gupta S, et al. MV CBCT based assessment of setup uncertainties and planning target volume margin in head and neck cancer. Reports of Practical Oncology and Radiotherapy. 2024. doi:10.5603/rpor.99361

BibTeX
@article{Sikdar2024,
  author = {Sikdar, Debanjan and Krishnan, Ajay S and Namitha, R S and Chakravarty, Abhishek and Gupta, Dhiraj and Gupta, Sweety and Kumar, Arvind and Joseph, Deepa and Gupta, Manoj},
  title = {MV CBCT based assessment of setup uncertainties and planning target volume margin in head and neck cancer},
  journal = {Reports of Practical Oncology and Radiotherapy},
  year = {2024},
  doi = {10.5603/rpor.99361}
}
Kostenlos starten →