CBCT-Based Dose Monitoring and Adaptive Planning Triggers in Head and Neck PBS Proton Therapy
Cancers · 30.07.2023 · 15 (15) · 3881
DOI: 10.3390/cancers15153881 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cancers, online erschienen am 30.07.2023. Verfasst von Keaton Reiners und 8 weiteren Autor:innen. Beteiligte Einrichtung: University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: IBA.
Abstract (Originalsprache)
Purpose
To investigate the feasibility of using cone-beam computed tomography (CBCT)-derived synthetic CTs to monitor the daily dose and trigger a plan review for adaptive proton therapy (APT) in head and neck cancer (HNC) patients.
Methods
For 84 HNC patients treated with proton pencil-beam scanning (PBS), same-day CBCT and verification CT (vfCT) pairs were retrospectively collected. The ground truth CT (gtCT) was created by deforming the vfCT to the same-day CBCT, and it was then used as a dosimetric baseline and for establishing plan review trigger recommendations. Two different synthetic CT algorithms were tested; the corrected CBCT (corrCBCT) was created using an iterative image correction method and the virtual CT (virtCT) was created by deforming the planning CT to the CBCT, followed by a low-density masking process. Clinical treatment plans were recalculated on the image sets for evaluation.
Results
Plan review trigger criteria for adaptive therapy were established after closely reviewing the cohort data. Compared to the vfCT, the corrCBCT and virtCT reliably produced dosimetric data more similar to the gtCT. The average discrepancy in D99 for high-risk clinical target volumes (CTV) was 1.1%, 0.7%, and 0.4% and for standard-risk CTVs was 1.8%, 0.5%, and 0.5% for the vfCT, corrCBCT, and virtCT, respectively.
Conclusion
Streamlined APT has been achieved with the proposed plan review criteria and CBCT-based synthetic CT workflow.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA.
- Medical Physics Graduate Program, University of Florida College of Medicine, Gainesville, FL 32610, USA.
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL 32610, USA.
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL 32224, USA.
- RaySearch Laboratories, SE-103 65 Stockholm, Sweden.
- Ion Beam Applications S.A., 1348 Louvain-la-Neuve, Belgium.
ORCID-Profile: Adam Holtzman, Rasmus Nilsson, Yawei Zhang
Förderung
- IBA
Zitieren
APA
Reiners, K., Dagan, R., Holtzman, A., Bryant, C., Andersson, S., Nilsson, R., Hong, L., Johnson, P., & Zhang, Y. (2023). CBCT-Based Dose Monitoring and Adaptive Planning Triggers in Head and Neck PBS Proton Therapy. Cancers, 15(15), 3881. https://doi.org/10.3390/cancers15153881
Vancouver
Reiners K, Dagan R, Holtzman A, Bryant C, Andersson S, Nilsson R, et al. CBCT-Based Dose Monitoring and Adaptive Planning Triggers in Head and Neck PBS Proton Therapy. Cancers. 2023;15(15):3881. doi:10.3390/cancers15153881
BibTeX
@article{Reiners2023,
author = {Reiners, Keaton and Dagan, Roi and Holtzman, Adam and Bryant, Curtis and Andersson, Sebastian and Nilsson, Rasmus and Hong, Liu and Johnson, Perry and Zhang, Yawei},
title = {CBCT-Based Dose Monitoring and Adaptive Planning Triggers in Head and Neck PBS Proton Therapy},
journal = {Cancers},
year = {2023},
volume = {15},
number = {15},
pages = {3881},
doi = {10.3390/cancers15153881}
}
EUVIMED