Usefulness of additional [99mTc]NaTcO4 SPECT/CT after standard combination of [99mTc]Tc-MIBI SPECT/CT and neck ultrasonography — improving the efficiency of parathyroid imaging in inconclusive cases
Nuclear Medicine Review · 2025
DOI: 10.5603/nmr.108880 ↗At a glance
Journal article in Nuclear Medicine Review, 2025. Written by Aleksandra Aulich and 4 co-authors. Institution: Department of Nuclear Medicine, Medical University of Lodz, Łódź, Poland. aaulich@csk.umed.pl. Major MEDLINE topics: Single Photon Emission Computed Tomography Computed Tomography, Technetium Tc 99m Sestamibi, Parathyroid Glands, Neck.
Abstract (original language)
Background
The current standard method in hyperparathyroidism imaging is the combination of [99mTc]Tc-methoxyisobutylisonitrile ([99mTc]Tc-MIBI) single photon emission computed tomography/computed tomography (SPECT/CT) and neck ultrasonography (nUS). However, [99mTc]Tc-MIBI scintigraphy has certain limitations; thus, alternative imaging techniques may be beneficial. The following paper discusses the usefulness of performing an additional 99mTc-pertechnetate ([99mTc]NaTcO4) SPECT/CT after a standard combination of [99mTc]Tc-MIBI SPECT/CT and neck ultrasonography to improve the efficiency of detecting parathyroid adenomas and/or hyperplasia in inconclusive cases. Material and methods: The authors retrospectively analyzed archived medical data of 58 patients who underwent parathyroid scintigraphy in 2022–2024. The study consists of patients, in whose cases [99mTc]Tc-MIBI SPECT/CT in combination with nUS did not provide a clear outcome. These patients underwent additional [99mTc]NaTcO4 SPECT/CT imaging. Radiotracer uptake in both studies was then compared visually.
Results
Out of 58 patients included in the study, 40 (69%) had positive [99mTc]Tc-MIBI and [99mTc]NaTcO4 SPECT/CT results, whereas 18 patients (31%) had a negative scintigraphy result. In 42 out of 58 cases, clinical verification of SPECT/CT results was obtained, based on which the sensitivity, specificity, and accuracy of the method were 83.3%.
Conclusions
This study demonstrates that additional [99mTc]NaTcO4 SPECT/CT can be valuable in patients with inconclusive results in [99mTc]Tc-MIBI SPECT/CT (evaluated in combination with nUS), both to confirm and exclude the presence of hyperfunctioning parathyroid glands.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Nuclear Medicine, Medical University of Lodz, Łódź, Poland. aaulich@csk.umed.pl.
- Department of Nuclear Medicine, Medical University of Lodz, Łódź, Poland.
ORCID profiles: Paweł Cichocki, Zbigniew Adamczewski
Cite
APA
Aulich, A., Dyczka, A., Dąbrowski, J., Cichocki, P., & Adamczewski, Z. (2025). Usefulness of additional [99mTc]NaTcO4 SPECT/CT after standard combination of [99mTc]Tc-MIBI SPECT/CT and neck ultrasonography — improving the efficiency of parathyroid imaging in inconclusive cases. Nuclear Medicine Review. https://doi.org/10.5603/nmr.108880
Vancouver
Aulich A, Dyczka A, Dąbrowski J, Cichocki P, Adamczewski Z. Usefulness of additional [99mTc]NaTcO4 SPECT/CT after standard combination of [99mTc]Tc-MIBI SPECT/CT and neck ultrasonography — improving the efficiency of parathyroid imaging in inconclusive cases. Nuclear Medicine Review. 2025. doi:10.5603/nmr.108880
BibTeX
@article{Aulich2025,
author = {Aulich, Aleksandra and Dyczka, Anita and Dąbrowski, Janusz and Cichocki, Paweł and Adamczewski, Zbigniew},
title = {Usefulness of additional [99mTc]NaTcO4 SPECT/CT after standard combination of [99mTc]Tc-MIBI SPECT/CT and neck ultrasonography — improving the efficiency of parathyroid imaging in inconclusive cases},
journal = {Nuclear Medicine Review},
year = {2025},
doi = {10.5603/nmr.108880}
}
EUVIMED