EUVIMEDEUVIMED entdecken
Crossref

Usefulness of additional [99mTc]NaTcO4 SPECT/CT after standard combination of [99mTc]Tc-MIBI SPECT/CT and neck ultrasonography — improving the efficiency of parathyroid imaging in inconclusive cases

Aleksandra Aulich, Anita Dyczka, Janusz Dąbrowski, Paweł Cichocki iD, Zbigniew Adamczewski iD

Nuclear Medicine Review · 2025

DOI: 10.5603/nmr.108880 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Medicine Review, 2025. Verfasst von Aleksandra Aulich und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Medical University of Lodz, Łódź, Poland. aaulich@csk.umed.pl. Hauptthemen laut MEDLINE: Single Photon Emission Computed Tomography Computed Tomography, Technetium Tc 99m Sestamibi, Parathyroid Glands, Neck.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The current standard method in hyperparathyroidism imaging is the combination of [99mTc]Tc-methoxyisobutylisonitrile ([99mTc]Tc-MIBI) single photon emission computed tomography/computed tomography (SPECT/CT) and neck ultrasonography (nUS). However, [99mTc]Tc-MIBI scintigraphy has certain limitations; thus, alternative imaging techniques may be beneficial. The following paper discusses the usefulness of performing an additional 99mTc-pertechnetate ([99mTc]NaTcO4) SPECT/CT after a standard combination of [99mTc]Tc-MIBI SPECT/CT and neck ultrasonography to improve the efficiency of detecting parathyroid adenomas and/or hyperplasia in inconclusive cases. Material and methods: The authors retrospectively analyzed archived medical data of 58 patients who underwent parathyroid scintigraphy in 2022–2024. The study consists of patients, in whose cases [99mTc]Tc-MIBI SPECT/CT in combination with nUS did not provide a clear outcome. These patients underwent additional [99mTc]NaTcO4 SPECT/CT imaging. Radiotracer uptake in both studies was then compared visually.

Results

Out of 58 patients included in the study, 40 (69%) had positive [99mTc]Tc-MIBI and [99mTc]NaTcO4 SPECT/CT results, whereas 18 patients (31%) had a negative scintigraphy result. In 42 out of 58 cases, clinical verification of SPECT/CT results was obtained, based on which the sensitivity, specificity, and accuracy of the method were 83.3%.

Conclusions

This study demonstrates that additional [99mTc]NaTcO4 SPECT/CT can be valuable in patients with inconclusive results in [99mTc]Tc-MIBI SPECT/CT (evaluated in combination with nUS), both to confirm and exclude the presence of hyperfunctioning parathyroid glands.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Single Photon Emission Computed Tomography Computed TomographyTechnetium Tc 99m SestamibiParathyroid GlandsNeckSodium Pertechnetate Tc 99mHumansMaleFemaleMiddle AgedRetrospective StudiesUltrasonographyAgedAdultAged, 80 and over

Stichwörter der Autor:innen

99mTc-Sestamibi scintigraphy99mTc-pertechnetate scintigraphySPECT/CThybrid imaginghyperparathyroidismparathyroid localization diagnostics

Substanzen

Technetium Tc 99m SestamibiSodium Pertechnetate Tc 99m

Autor:innen und Institutionen

  • Department of Nuclear Medicine, Medical University of Lodz, Łódź, Poland. aaulich@csk.umed.pl.
  • Department of Nuclear Medicine, Medical University of Lodz, Łódź, Poland.

ORCID-Profile: Paweł Cichocki, Zbigniew Adamczewski

Zitieren

APA

Aulich, A., Dyczka, A., Dąbrowski, J., Cichocki, P., & Adamczewski, Z. (2025). Usefulness of additional [99mTc]NaTcO4 SPECT/CT after standard combination of [99mTc]Tc-MIBI SPECT/CT and neck ultrasonography — improving the efficiency of parathyroid imaging in inconclusive cases. Nuclear Medicine Review. https://doi.org/10.5603/nmr.108880

Vancouver

Aulich A, Dyczka A, Dąbrowski J, Cichocki P, Adamczewski Z. Usefulness of additional [99mTc]NaTcO4 SPECT/CT after standard combination of [99mTc]Tc-MIBI SPECT/CT and neck ultrasonography — improving the efficiency of parathyroid imaging in inconclusive cases. Nuclear Medicine Review. 2025. doi:10.5603/nmr.108880

BibTeX
@article{Aulich2025,
  author = {Aulich, Aleksandra and Dyczka, Anita and Dąbrowski, Janusz and Cichocki, Paweł and Adamczewski, Zbigniew},
  title = {Usefulness of additional [99mTc]NaTcO4 SPECT/CT after standard combination of [99mTc]Tc-MIBI SPECT/CT and neck ultrasonography — improving the efficiency of parathyroid imaging in inconclusive cases},
  journal = {Nuclear Medicine Review},
  year = {2025},
  doi = {10.5603/nmr.108880}
}
Kostenlos starten →