EUVIMEDEUVIMED entdecken
Crossref

A calculation method for the concentricity of funnel-shaped microchannel plates

Shangtong Li, Hua Cai, Xuan Zhao, Jinsheng Jia, Xiang Li, Wang Qiao, Tianyi Na, Mengnan Ma, Wei Wang, Hui Liu

Advances in Engineering Technology Research · 24.03.2026 · 16 (1) · 815

DOI: 10.56028/aetr.16.1.815.2026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advances in Engineering Technology Research, online erschienen am 24.03.2026. Verfasst von Shangtong Li und 9 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microchannel plates (MCPs) are glass-based functional materials capable of parallel multiplication of charged particle flows in two-dimensional space. Due to their excellent electron amplification characteristics, compact size, and low noise, they are widely used in fields such as night vision, high-energy astrophysics, and particle detection.The open area ratio is the ratio of the channel opening area to the total working area of the MCP, determining the detection efficiency of the microchannel plate. Only when the charged particles enter the MCP channels can they be effectively amplified. By utilizing directional reactive ion etching or physical ion beam etching at a certain angle, the input surface of the MCP circular channel array is etched to a funnel shape with very thin channel walls. This significantly increases the open area ratio of the MCP input surface, thereby enhancing its detection efficiency.The concentricity of the expanded hole refers to the deviation distance of the channel’s center position before and after etching. The large concentricity means the channels are misaligned relative to the original center, which can lead to uneven distribution of the electric field inside the channels, causing degradation of the overall performance of the MCP . Thus, it is very important to measure the concentricity precisely. This paper proposes an effective method to measure the concentricity of funnel-shaped MCP. By combining microscopic images with Cartesian coordinates and using formulas to calculate the coordinates of the channel center before and after etching, the concentricity of the funnel-shaped MCP is determined. Furthermore, varying levels of concentricity experiments are performed utilizing this novel measuring method, and it was confirmed that MCPs with lower concentricity of the funnel-shaped MCP exhibit better amplification characteristics. This research overcomes the challenge of accurately characterizing the concentricity of the funnel-shaped MCP and provides assurance for the development of new design of MCPs.

Zitieren

APA

Li, S., Cai, H., Zhao, X., Jia, J., Li, X., Qiao, W., Na, T., Ma, M., Wang, W., & Liu, H. (2026). A calculation method for the concentricity of funnel-shaped microchannel plates. Advances in Engineering Technology Research, 16(1), 815. https://doi.org/10.56028/aetr.16.1.815.2026

Vancouver

Li S, Cai H, Zhao X, Jia J, Li X, Qiao W, et al. A calculation method for the concentricity of funnel-shaped microchannel plates. Advances in Engineering Technology Research. 2026;16(1):815. doi:10.56028/aetr.16.1.815.2026

BibTeX
@article{Li2026,
  author = {Li, Shangtong and Cai, Hua and Zhao, Xuan and Jia, Jinsheng and Li, Xiang and Qiao, Wang and Na, Tianyi and Ma, Mengnan and Wang, Wei and Liu, Hui},
  title = {A calculation method for the concentricity of funnel-shaped microchannel plates},
  journal = {Advances in Engineering Technology Research},
  year = {2026},
  volume = {16},
  number = {1},
  pages = {815},
  doi = {10.56028/aetr.16.1.815.2026}
}
Kostenlos starten →