EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Co-detection of isoproterenol and uric acid in biological and pharmaceutical samples at modified carbon paste electrode

Marib Ismail Ali, Ghofran Ali, Noor Hameed Neama Aziz

Journal of Electrochemical Science and Engineering · 11.08.2026 · 16

DOI: 10.5599/jese.3447 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Electrochemical Science and Engineering, online erschienen am 11.08.2026. Verfasst von Marib Ismail Ali und 2 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, cyclic voltammetry was used to examine the electrochemical characteristics of a carbon paste electrode modified with a manufactured Ni-based 1,3,5-benzene­tri­car­boxylate metal-organic framework nanostructure/graphene oxide nanocomposite. The modified electrode demonstrated outstanding electrocatalytic activity toward isoproterenol (IPT), with superior electrochemical performance, low overpotential, and high conductivity when used as an electrochemical sensor for the catalytic oxidation of IPT. It was found that under ideal conditions (pH 7.0), the oxidation potential of IPT would drop to approximately 170 mV at the modified electrode compared with an unmodified carbon paste electrode. A linear concen­tration range, 0.05 to 480.0 μM IPT, was demonstrated using differential pulse voltammetry. It was discovered that the IPT detection limit was 0.015 μM. To determine IPT in the presence of uric acid (UA), the selectivity of the developed electrochemical sensor was also examined. Ultimately, the developed sensor was used to detect IPT and UA in genuine drug samples and human urine, yielding satisfactory findings.

Zitieren

APA

Ali, M. I., Ali, G., & Aziz, N. H. N. (2026). Co-detection of isoproterenol and uric acid in biological and pharmaceutical samples at modified carbon paste electrode. Journal of Electrochemical Science and Engineering, 16. https://doi.org/10.5599/jese.3447

Vancouver

Ali MI, Ali G, Aziz NHN. Co-detection of isoproterenol and uric acid in biological and pharmaceutical samples at modified carbon paste electrode. Journal of Electrochemical Science and Engineering. 2026;16. doi:10.5599/jese.3447

BibTeX
@article{Ali2026,
  author = {Ali, Marib Ismail and Ali, Ghofran and Aziz, Noor Hameed Neama},
  title = {Co-detection of isoproterenol and uric acid in biological and pharmaceutical samples at modified carbon paste electrode},
  journal = {Journal of Electrochemical Science and Engineering},
  year = {2026},
  volume = {16},
  doi = {10.5599/jese.3447}
}
Kostenlos starten →