Application of a g-C 3 N 4 @nZVI/CNTs Modified Carbon Paste Electrode for Uric Acid Detection in Spiked Urine Samples

Aya A. Mouhamed, Ola G. Hussein, Maria Osama Mekhail, Tony Victor Zaki, Amr M. Mahmoud, Jeffrey G. Bell

ECS Sensors Plus · 01.12.2025 · 4 (4) · 043601

DOI: 10.1149/2754-2726/ae1bb7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ECS Sensors Plus, online erschienen am 18.11.2025. Verfasst von Aya A. Mouhamed und 5 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A carbon paste electrode (CPE) based on a g-C 3 N 4 @nZVI/CNT nanocomposite was fabricated via chemical reduction and subsequently evaluated towards electrochemical detection of uric acid (UA) via differential pulse voltammetry (DPV). During synthesis, graphitic carbon nitride (g-C 3 N 4 ) serves as a durable substrate with extensive surface area promoting the homogeneous distribution of nano zero-valent iron (nZVI) particles. Carbon nanotubes (CNTs) were incorporated into the composite to enhance electrical conductivity and mechanical stability. The subsequent nanocomposite was characterized by scanning electron microscopy and energy-dispersive X-ray spectroscopy, confirming the successful integration of g-C 3 N 4 , nZVI, and CNTs with well-dispersed iron nanoparticles on the g-C 3 N 4 matrix. The resulting g-C 3 N 4 @nZVI/CNT-modified CPE demonstrated superior electrochemical sensitivity toward UA as evidenced by a pronounced increase in peak current during DPV analysis compared to bare and individually modified electrodes. Under optimized conditions, the sensor exhibited a linear response of 2.0–100.0 μM and detection limit of 1.7 μM. The electrode maintained high selectivity in the presence of common interferants with good repeatability and long-term operational stability. These findings highlight the synergistic interaction among g-C 3 N 4 , nZVI, and CNTs in boosting electron transfer and catalytic activity, making this composite a promising, cost-effective, and scalable solution for sensitive UA detection in clinical diagnostics and environmental monitoring.

Zitieren

APA

Mouhamed, A. A., Hussein, O. G., Mekhail, M. O., Zaki, T. V., Mahmoud, A. M., & Bell, J. G. (2025). Application of a g-C 3 N 4 @nZVI/CNTs Modified Carbon Paste Electrode for Uric Acid Detection in Spiked Urine Samples. ECS Sensors Plus, 4(4), 043601. https://doi.org/10.1149/2754-2726/ae1bb7

Vancouver

Mouhamed AA, Hussein OG, Mekhail MO, Zaki TV, Mahmoud AM, Bell JG. Application of a g-C 3 N 4 @nZVI/CNTs Modified Carbon Paste Electrode for Uric Acid Detection in Spiked Urine Samples. ECS Sensors Plus. 2025;4(4):043601. doi:10.1149/2754-2726/ae1bb7

BibTeX
@article{Mouhamed2025,
  author = {Mouhamed, Aya A. and Hussein, Ola G. and Mekhail, Maria Osama and Zaki, Tony Victor and Mahmoud, Amr M. and Bell, Jeffrey G.},
  title = {Application of a g-C 3 N 4 @nZVI/CNTs Modified Carbon Paste Electrode for Uric Acid Detection in Spiked Urine Samples},
  journal = {ECS Sensors Plus},
  year = {2025},
  volume = {4},
  number = {4},
  pages = {043601},
  doi = {10.1149/2754-2726/ae1bb7}
}
Kostenlos starten →